Low voltage power cables are built to IEC and BS requirements, with a rated voltage of 0.6/1KV.
These cables are used to distribute electricity in metropolitan networks, industrial facilities, and electrical machinery.
They are excellent for both indoor and outdoor applications, as well as moist and wet environments.
- Copper Conductor PVC Insulated Cable (Unarmoured)
- PVC Insulated, PVC Sheathed Unarmoured Cables CU / PVC / PVC Single Core
- PVC Insulated, PVC Sheathed Unarmoured Cables CU / PVC / PVC Two Core
- PVC Insulated, PVC Sheathed Unarmoured Cables CU / PVC / PVC Three Core
- PVC Insulated, PVC Sheathed Unarmoured Cables CU / PVC / PVC Four Core With Reduced Neutral
- PVC Insulated, PVC Sheathed Unarmoured Cables CU / PVC / PVC Four Core
- PVC Insulated, PVC Sheathed Unarmoured Cables CU / PVC / PVC Five Core
- Copper conductor PVC Insulated Cable (Armoured)
- Copper conductor XLPE Insulated Cable (Unarmoured)
- Copper Conductor XLPE Insulated Cable (Armoured)
- ABC Cables
Copper Conductor PVC Insulated Cable (Unarmoured)
PVC Insulated, PVC Sheathed Unarmoured Cables CU / PVC / PVC Single Core
Standard: | IEC 60502-1 | Conductor: | Class 2 stranded copper as per IEC 60228, BS EN 60228. |
Rated Voltage: | 0.6/1 KV | Insulation: | PVC insulation type A as per IEC 60502-1 or type TI1 as per BS EN 50363 temperature rating 70 oC. (PVC 90 oC is available on request). |
Shape of Conductor: | 16 mm2 and below, conductor shall be circular stranded non-compacted. 25 mm2 and above, conductor shall be circular stranded compacted. | Outer Sheath: | PVC outer sheath type ST1 as per IEC 60502-1 or type TM1 as per BS EN 50363. |
Applications: | For outdoor and indoor installations in damp and wet locations. They are normally used for power distribution in urban networks, industrial plants and energy distribution. |
Order No. | Item Code No. | Nominal Area | Nominal Insulation Thickness | Nominal Outer Sheath Thickness | Approx. Overall Diameter* | Approx. Cable Weight** | Standard Length |
No. x mm2 | mm | mm | mm | Kg/Km | (mtr. ± 5%) | ||
L001 | U1L1-11400R-20002K-S | 1 x 10 | 1.0 | 1.4 | 9 | 175 | 1000 |
L002 | U1L1-11500R-20002K-S | 1 x 16 | 1.0 | 1.4 | 10 | 235 | 1000 |
L003 | U1L1-11600C-20002K-S | 1 x 25 | 1.2 | 1.4 | 12 | 330 | 1000 |
L004 | U1L1-11700C-20002K-S | 1 x 35 | 1.2 | 1.4 | 13 | 430 | 1000 |
L005 | U1L1-11800C-20002K-S | 1 x 50 | 1.4 | 1.4 | 14 | 575 | 1000 |
L006 | U1L1-11900C-20002K-S | 1 x 70 | 1.4 | 1.4 | 16 | 775 | 1000 |
L007 | U1L1-12000C-20002K-S | 1 x 95 | 1.6 | 1.5 | 18 | 1050 | 1000 |
L008 | U1L1-12100C-20002K-S | 1 x 120 | 1.6 | 1.5 | 20 | 1300 | 1000 |
L009 | U1L1-12200C-20002K-S | 1 x 150 | 1.8 | 1.6 | 22 | 1575 | 1000 |
L010 | U1L1-12200C-20002K-S | 1 x 185 | 2.0 | 1.7 | 24 | 1975 | 1000 |
L011 | U1L1-12400C-20002K-S | 1 x 240 | 2.2 | 1.8 | 27 | 2550 | 1000 |
L012 | U1L1-12500C-20002K-S | 1 x 300 | 2.4 | 1.9 | 30 | 3175 | 1000 |
L013 | U1L1-12600C-20002K-S | 1 x 400 | 2.6 | 2.0 | 33 | 4025 | 500 |
L014 | U1L1-12700C-20002K-S | 1 x 500 | 2.8 | 2.1 | 37 | 5100 | 500 |
L015 | U1L1-12900C-20002K-S | 1 x 630 | 2.8 | 2.2 | 41 | 6475 | 500 |
PVC Insulated, PVC Sheathed Unarmoured Cables CU / PVC / PVC Two Core
Standard: | IEC 60502-1 | Conductor: | Class 1 solid (up to 6 mm2 upon request) copper or class 2 stranded copper as per IEC 60228, BS EN 60228. |
Rated Voltage: | 0.6/1 KV | Insulation: | PVC insulation type A as per IEC 60502-1 or type TI1 as per BS EN 50363 temperature rating 70 oC. (PVC 90 oC is available on request). |
Shape of Conductor: | 16 mm2 and below, conductor shall be circular stranded non-compacted. 25 mm2 and above, conductor shall be circular stranded compacted. | Outer Sheath: | PVC outer sheath type ST1 as per IEC 60502-1 or type TM1 as per BS EN 50363. |
| | Applications: | For outdoor and indoor installations in damp and wet locations. They are normally used for power distribution in urban networks, industrial plants and energy distribution. |
Order No. | Item Code No. | Nominal Area | Nominal Insulation Thickness | Nominal Outer Sheath Thickness | Approx. Overall Diameter* | Approx. Cable Weight** | Standard Length |
No. x mm2 | mm | mm | mm | Kg/Km | (mtr. ± 5%) | ||
L016 | U1L1-20800R-20002K-S | 2 x 1.5 | 0.8 | 1.8 | 10 | 150 | 1000 |
L017 | U1L1-21000R-20002K-S | 2 x 2.5 | 0.8 | 1.8 | 11 | 190 | 1000 |
L018 | U1L1-21200R-20002K-S | 2 x 4.0 | 1.0 | 1.8 | 13 | 260 | 1000 |
L019 | U1L1-21300R-20002K-S | 2 x 6.0 | 1.0 | 1.8 | 14 | 330 | 1000 |
L020 | U1L1-21400R-20R02K-S | 2 x 10 | 1.0 | 1.8 | 18 | 575 | 1000 |
L021 | U1L1-21500R-20R02K-S | 2 x 16 | 1.0 | 1.8 | 20 | 760 | 1000 |
L022 | U1L1-21600C-20202K-S | 2 x 25 | 1.2 | 1.8 | 23 | 975 | 1000 |
L023 | U1L1-21700C-20202K-S | 2 x 35 | 1.2 | 1.8 | 25 | 1250 | 1000 |
L024 | U1L1-21800C-20202K-S | 2 x 50 | 1.4 | 1.8 | 29 | 1650 | 1000 |
L025 | U1L1-21900C-20202K-S | 2 x 70 | 1.4 | 1.9 | 32 | 2225 | 500 |
L026 | U1L1-22000C-20202K-S | 2 x 95 | 1.6 | 2.0 | 37 | 2975 | 500 |
L027 | U1L1-22100C-20202K-S | 2 x 120 | 1.6 | 2.1 | 40 | 3575 | 500 |
L028 | U1L1-22200C-20202K-S | 2 x 150 | 1.8 | 2.2 | 44 | 4475 | 500 |
L029 | U1L1-22300C-20202K-S | 2 x 185 | 2.0 | 2.4 | 48 | 5475 | 500 |
L030 | U1L1-22400C-20202K-S | 2 x 240 | 2.2 | 2.6 | 55 | 7100 | 250 |
L031 | U1L1-22500C-20202K-S | 2 x 300 | 2.4 | 2.7 | 60 | 8700 | 250 |
PVC Insulated, PVC Sheathed Unarmoured Cables CU / PVC / PVC Three Core
Standard: | IEC 60502-1 | Conductor: | Class 1 solid (up to 6 mm2 upon request) copper or class 2 stranded copper as per IEC 60228, BS EN 60228. |
Rated Voltage: | 0.6/1 KV | Insulation: | PVC insulation type A as per IEC 60502-1 or type TI1 as per BS EN 50363 temperature rating 70 oC. (PVC 90 oC is available on request). |
Shape of Conductor: | 16 mm2 and below, conductor shall be circular stranded non-compacted. 25 mm2 and above, conductor shall be sectoral stranded compacted. | Outer Sheath: | PVC outer sheath type ST1 as per IEC 60502-1 or type TM1 as per BS EN 50363. |
| | Applications: | For outdoor and indoor installations in damp and wet locations. They are normally used for power distribution in urban networks, industrial plants and energy distribution. |
Order No. | Item Code No. | Nominal Area | Nominal Insulation Thickness | Nominal Outer Sheath Thickness | Approx. Overall Diameter* | Approx. Cable Weight** | Standard Length |
No. x mm2 | mm | mm | mm | Kg/Km | (mtr. ± 5%) | ||
L032 | U1L1-30800R-20002K-S | 3 x 1.5 | 0.8 | 1.8 | 11 | 175 | 1000 |
L033 | U1L1-31000R-20002K-S | 3 x 2.5 | 0.8 | 1.8 | 12 | 225 | 1000 |
L034 | U1L1-31200R-20002K-S | 3 x 4.0 | 1.0 | 1.8 | 14 | 315 | 1000 |
L035 | U1L1-31300R-20002K-S | 3 x 6.0 | 1.0 | 1.8 | 15 | 400 | 1000 |
L036 | U1L1-31400R-20R02K-S | 3 x 10 | 1.0 | 1.8 | 19 | 675 | 1000 |
L037 | U1L1-31500R-20R02K-S | 3 x 16 | 1.0 | 1.8 | 20 | 925 | 1000 |
L038 | U1L1-31600S-20002K-S | 3 x 25 | 1.2 | 1.8 | 20 | 975 | 1000 |
L039 | U1L1-31700S-20002K-S | 3 x 35 | 1.2 | 1.8 | 22 | 1275 | 1000 |
L040 | U1L1-31800S-20002K-S | 3 x 50 | 1.4 | 1.8 | 25 | 1700 | 1000 |
L041 | U1L1-31900S-20002K-S | 3 x 70 | 1.4 | 1.9 | 28 | 2325 | 1000 |
L042 | U1L1-32000S-20002K-S | 3 x 95 | 1.6 | 2.1 | 32 | 3200 | 500 |
L043 | U1L1-32100S-20002K-S | 3 x 120 | 1.6 | 2.2 | 34 | 3900 | 500 |
L044 | U1L1-32200S-20002K-S | 3 x 150 | 1.8 | 2.3 | 38 | 4875 | 500 |
L045 | U1L1-32300S-20002K-S | 3 x 185 | 2.0 | 2.5 | 42 | 6025 | 500 |
L046 | U1L1-32400S-20002K-S | 3 x 240 | 2.2 | 2.7 | 47 | 7800 | 250 |
L047 | U1L1-32500S-20002K-S | 3 x 300 | 2.4 | 2.9 | 52 | 9700 | 250 |
PVC Insulated, PVC Sheathed Unarmoured Cables CU / PVC / PVC Four Core With Reduced Neutral
Standard: | IEC 60502-1 | Conductor: | Class 2 stranded copper as per IEC 60228, BS EN 60228. |
Rated Voltage: | 0.6/1 KV | Insulation: | PVC insulation type A as per IEC 60502-1 or type TI1 as per BS EN 50363 temperature rating 70 oC. (PVC 90 oC is available on request). |
Shape of Conductor: | 16 mm2 and below, conductor shall be circular stranded non-compacted. 25 mm2 and above, conductor shall be sectoral stranded compacted. | Outer Sheath: | PVC outer sheath type ST1 as per IEC 60502-1 or type TM1 as per BS EN 50363. |
| | Applications: | For outdoor and indoor installations in damp and wet locations. They are normally used for power distribution in urban networks, industrial plants and energy distribution. |
Order No. | Item Code No. | Nominal Area | Nominal Insulation Thickness (mm) | Nominal Outer Sheath Thickness | Approx. Overall Diameter* | Approx. Cable Weight** | Standard Length | |
No. x mm2 | Ph.• | Ne.• | mm | mm | Kg/Km | (mtr. ± 5%) | ||
L048 | U1L1-41413R-20R02K-S | 3 x 10 + 6 | 1.0 | 1.0 | 1.8 | 20 | 775 | 1000 |
L049 | U1L1-41514R-20R02K-S | 3 x 16 + 10 | 1.0 | 1.0 | 1.8 | 22 | 1050 | 1000 |
L050 | U1L1-41615S-20002K-S | 3 x 25 + 16 | 1.2 | 1.0 | 1.8 | 24 | 1275 | 1000 |
L051 | U1L1-41715S-20002K-S | 3 x 35 + 16 | 1.2 | 1.0 | 1.8 | 25 | 1475 | 1000 |
L052 | U1L1-41816S-20002K-S | 3 x 50 + 25 | 1.4 | 1.2 | 1.9 | 29 | 2000 | 1000 |
L053 | U1L1-41917S-20002K-S | 3 x 70 + 35 | 1.4 | 1.2 | 2.0 | 32 | 2725 | 500 |
L054 | U1L1-42018S-20002K-S | 3 x 95 + 50 | 1.6 | 1.4 | 2.1 | 37 | 3750 | 500 |
L055 | U1L1-42119S-20002K-S | 3 x 120 + 70 | 1.6 | 1.4 | 2.2 | 40 | 4650 | 500 |
L056 | U1L1-42219S-20002K-S | 3 x 150 + 70 | 1.8 | 1.4 | 2.4 | 44 | 5650 | 500 |
L057 | U1L1-42320S-20002K-S | 3 x 185 + 95 | 2.0 | 1.6 | 2.5 | 49 | 7075 | 250 |
L058 | U1L1-42421S-20002K-S | 3 x 240 + 120 | 2.2 | 1.6 | 2.7 | 55 | 9100 | 250 |
L059 | U1L1-42522S-20002K-S | 3 x 300 + 150 | 2.4 | 1.8 | 2.9 | 61 | 11300 | 250 |
PVC Insulated, PVC Sheathed Unarmoured Cables CU / PVC / PVC Four Core
Standard: | IEC 60502-1 | Conductor: | Class 2 stranded copper as per IEC 60228, BS EN 60228. |
Rated Voltage: | 0.6/1 KV | Insulation: | PVC insulation type A as per IEC 60502-1 or type TI1 as per BS EN 50363 temperature rating 70 oC. (PVC 90 oC is available on request). |
Shape of Conductor: | 16 mm2 and below, conductor shall be circular stranded non-compacted. 25 mm2 and above, conductor shall be sectoral stranded compacted. | Outer Sheath: | PVC outer sheath type ST1 as per IEC 60502-1 or type TM1 as per BS EN 50363. |
| | Applications: | For outdoor and indoor installations in damp and wet locations. They are normally used for power distribution in urban networks, industrial plants and energy distribution. |
Order No. | Item Code No. | Nominal Area | Nominal Insulation Thickness | Nominal Outer Sheath Thickness | Approx. Overall Diameter* | Approx. Cable Weight** | Standard Length |
No. x mm2 | mm | mm | mm | Kg/Km | (mtr. ± 5%) | ||
L060 | U1L1-40800R-20002K-S | 4 x 1.5 | 0.8 | 1.8 | 12 | 210 | 1000 |
L061 | U1L1-41000R-20002K-S | 4 x 2.5 | 0.8 | 1.8 | 13 | 275 | 1000 |
L062 | U1L1-41200R-20002K-S | 4 x 4.0 | 1.0 | 1.8 | 15 | 400 | 1000 |
L063 | U1L1-41300R-20002K-S | 4 x 6.0 | 1.0 | 1.8 | 16 | 500 | 1000 |
L064 | U1L1-41400R-20R02K-S | 4 x 10 | 1.0 | 1.8 | 21 | 825 | 1000 |
L065 | U1L1-41500R-20R02K-S | 4 x 16 | 1.0 | 1.8 | 23 | 1150 | 1000 |
L066 | U1L1-41600S-20002K-S | 4 x 25 | 1.2 | 1.8 | 23 | 1275 | 1000 |
L067 | U1L1-41700S-20002K-S | 4 x 35 | 1.2 | 1.8 | 26 | 1675 | 1000 |
L068 | U1L1-41800S-20002K-S | 4 x 50 | 1.4 | 1.9 | 30 | 2250 | 1000 |
L069 | U1L1-41900S-20002K-S | 4 x 70 | 1.4 | 2.1 | 33 | 3100 | 500 |
L070 | U1L1-42000S-20002K-S | 4 x 95 | 1.6 | 2.2 | 38 | 4250 | 500 |
L071 | U1L1-42100S-20002K-S | 4 x 120 | 1.6 | 2.3 | 41 | 5200 | 500 |
L072 | U1L1-42200S-20002K-S | 4 x 150 | 1.8 | 2.5 | 46 | 6500 | 500 |
L073 | U1L1-42300S-20002K-S | 4 x 185 | 2.0 | 2.7 | 51 | 8050 | 250 |
L074 | U1L1-42400S-20002K-S | 4 x 240 | 2.2 | 2.9 | 57 | 10400 | 250 |
L075 | U1L1-42500S-20002K-S | 4 x 300 | 2.4 | 3.1 | 63 | 12950 | 250 |
PVC Insulated, PVC Sheathed Unarmoured Cables CU / PVC / PVC Five Core
Standard: | IEC 60502-1 | Conductor: | Class 2 stranded copper as per IEC 60228, BS EN 60228. |
Rated Voltage: | 0.6/1 KV | Insulation: | PVC insulation type A as per IEC 60502-1 or type TI1 as per BS EN 50363 temperature rating 70 oC. (PVC 90 oC is available on request). |
Shape of Conductor: | 16 mm2 and below, conductor shall be circular stranded non-compacted. 25 mm2 and above, conductor shall be sectoral stranded compacted. | Outer Sheath: | PVC outer sheath type ST1 as per IEC 60502-1 or type TM1 as per BS EN 50363. |
| | Applications: | For outdoor and indoor installations in damp and wet locations. They are normally used for power distribution in urban networks, industrial plants and energy distribution. |
Order No. | Item Code No. | Nominal Area | Nominal Insulation Thickness | Nominal Outer Sheath Thickness | Approx. Overall Diameter* | Approx. Cable Weight** | Standard Length |
No. x mm2 | mm | mm | mm | Kg/Km | (mtr. ± 5%) | ||
L076 | U1L1-50800R-20002K-S | 5 x 1.5 | 0.8 | 1.8 | 13 | 250 | 1000 |
L077 | U1L1-51000R-20002K-S | 5 x 2.5 | 0.8 | 1.8 | 14 | 325 | 1000 |
L078 | U1L1-51200R-20002K-S | 5 x 4.0 | 1.0 | 1.8 | 16 | 475 | 1000 |
L079 | U1L1-51300R-20002K-S | 5 x 6.0 | 1.0 | 1.8 | 18 | 615 | 1000 |
L080 | U1L1-51400R-20R02K-S | 5 x 10 | 1.0 | 1.8 | 22 | 1020 | 1000 |
L081 | U1L1-51500R-20R02K-S | 5 x 16 | 1.0 | 1.8 | 25 | 1400 | 1000 |
L082 | U1L1-51600C-20202K-S | 5 x 25 | 1.2 | 1.8 | 29 | 1900 | 500 |
L083 | U1L1-51700C-20202K-S | 5 x 35 | 1.2 | 1.9 | 32 | 2550 | 500 |
L084 | U1L1-51800C-20202K-S | 5 x 50 | 1.4 | 2.0 | 37 | 3400 | 500 |
L085 | U1L1-51900C-20202K-S | 5 x 70 | 1.4 | 2.2 | 42 | 4600 | 500 |
Copper conductor PVC Insulated Cable (Armoured)
PVC Insulated, PVC Sheathed Armoured Cables CU / PVC / AWA / PVC Single Core
tandard: | IEC 60502-1, BS 6346 | Conductor: | Class 2 stranded copper as per IEC 60228, BS EN 60228 |
Rated Voltage: | 0.6/1 KV | Insulation: | PVC insulation type A as per IEC 60502-1 or type TI1 as per BS EN 50363 temperature rating 70 o C. (PVC 90 o C is available on request). |
Shape of Conductor: | Conductor shall be circular stranded compacted. | Outer Sheath: | PVC outer sheath type ST1 as per IEC 60502-1 or type TM1 as per BS EN 50363. |
Armour: | Aluminum wires applied helically as per IEC 60502-1 or BS 6346 | Applications: | For outdoor installations in damp and wet locations. They are normally used for power distribution in urban networks, industrial plants and energy distribution where mechanical damage expected to occur. |
Order No. | Item Code No. | Nominal Area | Nominal Insulation Thickness | Nominal Aluminum Wire Diameter | Nominal Outer Sheath Thickness | Approx. Overall Diameter* | Approx. Cable Weight** | Standard Length |
No. x mm2 | mm | mm | mm | mm | Kg/Km | (mtr. ± 5%) | ||
L086 | U1L1-11800C-20222K-S | 1 x 50 | 1.4 | 1.25 | 1.8 | 20 | 850 | 1000 |
L087 | U1L1-11900C-20222K-S | 1 x 70 | 1.4 | 1.25 | 1.8 | 21 | 1075 | 1000 |
L088 | U1L1-12000C-20222K-S | 1 x 95 | 1.6 | 1.25 | 1.8 | 23 | 1400 | 1000 |
L089 | U1L1-12100C-20222K-S | 1 x 120 | 1.6 | 1.60 | 1.8 | 26 | 1700 | 1000 |
L090 | U1L1-12200C-20222K-S | 1 x 150 | 1.8 | 1.60 | 1.8 | 27 | 2050 | 1000 |
L091 | U1L1-12300C-20222K-S | 1 x 185 | 2.0 | 1.60 | 1.8 | 29 | 2450 | 1000 |
L092 | U1L1-12400C-20222K-S | 1 x 240 | 2.2 | 1.60 | 1.9 | 32 | 3100 | 500 |
L093 | U1L1-12500C-20222K-S | 1 x 300 | 2.4 | 2.00 | 2.0 | 36 | 3900 | 500 |
L094 | U1L1-12600C-20222K-S | 1 x 400 | 2.6 | 2.00 | 2.1 | 40 | 4850 | 500 |
L095 | U1L1-12700C-20222K-S | 1 x 500 | 2.8 | 2.00 | 2.2 | 44 | 5975 | 500 |
L096 | U1L1-12900C-20222K-S | 1 x 630 | 2.8 | 2.00 | 2.4 | 47 | 7366 | 500 |
PVC Insulated, PVC Sheathed Armoured Cables CU / PVC / SWA / PVC Two Core
tandard: | IEC 60502-1, BS 6346 | Conductor: | Class 2 stranded copper as per IEC 60228, BS EN 60228 |
Rated Voltage: | 0.6/1 KV | Insulation: | PVC insulation type A as per IEC 60502-1 or type TI1 as per BS EN 50363 temperature rating 70 o C. (PVC 90 o C is available on request). |
Shape of Conductor: | Conductor shall be circular stranded compacted. | Outer Sheath: | PVC outer sheath type ST1 as per IEC 60502-1 or type TM1 as per BS EN 50363. |
Armour: | Galvanized steel wires applied helically as per IEC 60502-1 or BS 6346 | Applications: | For outdoor installations in damp and wet locations. They are normally used for power distribution in urban networks, industrial plants and energy distribution where mechanical damage expected to occur. |
Order No. | Item Code No. | Nominal Area | Nominal Insulation Thickness | Nominal Aluminum Wire Diameter | Nominal Outer Sheath Thickness | Approx. Overall Diameter* | Approx. Cable Weight** | Standard Length |
No. x mm2 | mm | mm | mm | mm | Kg/Km | (mtr. ± 5%) | ||
L097 | U1L1-20800R-20212K-S | 2 x 1.5 | 0.8 | 0.9 | 1.8 | 14 | 375 | 1000 |
L098 | U1L1-21000R-20212K-S | 2 x 2.5 | 0.8 | 0.9 | 1.8 | 15 | 435 | 1000 |
L099 | U1L1-21200R-20212K-S | 2 x 4.0 | 1.0 | 0.9 | 1.8 | 17 | 550 | 1000 |
L100 | U1L1-21300R-20212K-S | 2 x 6.0 | 1.0 | 1.25 | 1.8 | 19 | 730 | 1000 |
L101 | U1L1-21400R-20212K-S | 2 x 10 | 1.0 | 1.25 | 1.8 | 21 | 925 | 1000 |
L102 | U1L1-21500R-20212K-S | 2 x 16 | 1.0 | 1.25 | 1.8 | 23 | 1150 | 1000 |
L103 | U1L1-21600C-20212K-S | 2 x 25 | 1.2 | 1.6 | 1.8 | 26 | 1625 | 1000 |
L104 | U1L1-21700C-20212K-S | 2 x 35 | 1.2 | 1.6 | 1.8 | 28 | 1975 | 1000 |
L105 | U1L1-21800C-20212K-S | 2 x 50 | 1.4 | 1.6 | 1.9 | 32 | 2500 | 500 |
L106 | U1L1-21900C-20212K-S | 2 x 70 | 1.4 | 2.0 | 2.0 | 36 | 3400 | 500 |
L107 | U1L1-22000C-20212K-S | 2 x 95 | 1.6 | 2.0 | 2.2 | 41 | 4325 | 500 |
L108 | U1L1-22100C-20212K-S | 2 x 120 | 1.6 | 2.0 | 2.3 | 44 | 5050 | 500 |
L109 | U1L1-22200C-20212K-S | 2 x 150 | 1.8 | 2.0 | 2.4 | 49 | 6550 | 500 |
L110 | U1L1-22300C-20212K-S | 2 x 185 | 2.0 | 2.5 | 2.6 | 54 | 7750 | 250 |
L111 | U1L1-22400C-20212K-S | 2 x 240 | 2.2 | 2.5 | 2.8 | 60 | 9625 | 250 |
L112 | U1L1-22500C-20212K-S | 2 x 300 | 2.4 | 2.5 | 2.9 | 65 | 11550 | 250 |
PVC Insulated, PVC Sheathed Armoured Cables CU / PVC / SWA / PVC Three Core
tandard: | IEC 60502-1, BS 6346 | Conductor: | Class 2 stranded copper as per IEC 60228, BS EN 60228 |
Rated Voltage: | 0.6/1 KV | Insulation: | PVC insulation type A as per IEC 60502-1 or type TI1 as per BS EN 50363 temperature rating 70 o C. (PVC 90 o C is available on request). |
Shape of Conductor: | Conductor shall be circular stranded compacted. | Outer Sheath: | PVC outer sheath type ST1 as per IEC 60502-1 or type TM1 as per BS EN 50363. |
Armour: | Galvanized steel wires applied helically as per IEC 60502-1 or BS 6346 | Applications: | For outdoor installations in damp and wet locations. They are normally used for power distribution in urban networks, industrial plants and energy distribution where mechanical damage expected to occur. |
Order No. | Item Code No. | Nominal Area | Nominal Insulation Thickness | Nominal Steel Wire Diameter | Nominal Outer Sheath Thickness | Approx. Overall Diameter* | Approx. Cable Weight** | Standard Length |
No. x mm2 | mm | mm | mm | mm | Kg/Km | (mtr. ± 5%) | ||
L113 | U1L1-30800R-20212K-S | 3 x 1.5 | 0.8 | 0.9 | 1.8 | 15 | 425 | 1000 |
L114 | U1L1-31000R-20212K-S | 3 x 2.5 | 0.8 | 0.9 | 1.8 | 16 | 500 | 1000 |
L115 | U1L1-31200R-20212K-S | 3 x 4.0 | 1.0 | 1.25 | 1.8 | 18 | 725 | 1000 |
L116 | U1L1-31300R-20212K-S | 3 x 6.0 | 1.0 | 1.25 | 1.8 | 20 | 850 | 1000 |
L117 | U1L1-31400R-20212K-S | 3 x 10 | 1.0 | 1.25 | 1.8 | 22 | 1075 | 1000 |
L118 | U1L1-31500R-20212K-S | 3 x 16 | 1.0 | 1.25 | 1.8 | 24 | 1350 | 1000 |
L119 | U1L1-31600S-20212K-S | 3 x 25 | 1.2 | 1.6 | 1.8 | 24 | 1700 | 1000 |
L120 | U1L1-31700S-20212K-S | 3 x 35 | 1.2 | 1.6 | 1.8 | 26 | 2075 | 1000 |
L121 | U1L1-31800S-20212K-S | 3 x 50 | 1.4 | 1.6 | 2.0 | 30 | 2650 | 1000 |
L122 | U1L1-31900S-20212K-S | 3 x 70 | 1.4 | 2.0 | 2.1 | 34 | 3550 | 500 |
L123 | U1L1-32000S-20212K-S | 3 x 95 | 1.6 | 2.0 | 2.2 | 38 | 4650 | 500 |
L124 | U1L1-32100S-20212K-S | 3 x 120 | 1.6 | 2.0 | 2.3 | 40 | 5450 | 500 |
L125 | U1L1-32200S-20212K-S | 3 x 150 | 1.8 | 2.5 | 2.5 | 46 | 7025 | 500 |
L126 | U1L1-32300S-20212K-S | 3 x 185 | 2.0 | 2.5 | 2.7 | 50 | 8400 | 500 |
L127 | U1L1-32400S-20212K-S | 3 x 240 | 2.2 | 2.5 | 2.9 | 55 | 10450 | 250 |
L128 | U1L1-32500S-20212K-S | 3 x 300 | 2.4 | 2.5 | 3.1 | 60 | 12700 | 250 |
Order No. | Item Code No. | Nominal Area | Nominal Insulation Thickness(mm) | Nominal Steel Wire Diameter | Nominal Outer Sheath Thickness | Approx. Overall Diameter* | Approx. Cable Weight** | Standard Length | |
No. x mm2 | Ph.• | Ne.• | mm | mm | mm | Kg/Km | (mtr. ± 5%) | ||
L129 | U1L1-41413R-20212K-S | 3 x 10 + 6 | 1.0 | 1.0 | 1.25 | 1.8 | 23 | 1150 | 1000 |
L130 | U1L1-41514R-20212K-S | 3 x 16 + 10 | 1.0 | 1.0 | 1.60 | 1.8 | 26 | 1625 | 1000 |
L131 | U1L1-41615S-20212K-S | 3 x 25 + 16 | 1.2 | 1.0 | 1.60 | 1.8 | 27 | 1950 | 1000 |
L132 | U1L1-41715S-20212K-S | 3 x 35 + 16 | 1.2 | 1.0 | 1.60 | 1.8 | 30 | 2350 | 1000 |
L133 | U1L1-41816S-20212K-S | 3 x 50 + 25 | 1.4 | 1.2 | 2.00 | 2.0 | 35 | 3275 | 500 |
L134 | U1L1-41917S-20212K-S | 3 x 70 + 35 | 1.4 | 1.2 | 2.00 | 2.1 | 38 | 4200 | 500 |
L135 | U1L1-42018S-20212K-S | 3 x 95 + 50 | 1.6 | 1.4 | 2.00 | 2.2 | 43 | 5400 | 500 |
L136 | U1L1-42119S-20212K-S | 3 x 120 + 70 | 1.6 | 1.4 | 2.50 | 2.4 | 47 | 6900 | 500 |
L137 | U1L1-42219S-20212K-S | 3 x 150 + 70 | 1.8 | 1.4 | 2.50 | 2.5 | 52 | 8150 | 250 |
L138 | U1L1-42320S-20212K-S | 3 x 185 + 95 | 2.0 | 1.6 | 2.50 | 2.7 | 57 | 9850 | 250 |
L139 | U1L1-42421S-20212K-S | 3 x 240 + 120 | 2.2 | 1.6 | 2.50 | 2.9 | 63 | 12300 | 250 |
L140 | U1L1-42522S-20212K-S | 3 x 300 + 150 | 2.4 | 1.8 | 2.50 | 3.1 | 69 | 14800 | 250 |
Order No. | Item Code No. | Nominal Area | Nominal Insulation Thickness | Nominal Steel Wire Diameter | Nominal Outer Sheath Thickness | Approx. Overall Diameter* | Approx. Cable Weight** | Standard Length |
No. x mm2 | mm | mm | mm | mm | Kg/Km | (mtr. ± 5%) | ||
L141 | U1L1-40800R-20212K-S | 4 x 1.5 | 0.8 | 0.90 | 1.8 | 16 | 475 | 1000 |
L142 | U1L1-41000R-20212K-S | 4 x 2.5 | 0.8 | 0.90 | 1.8 | 17 | 550 | 1000 |
L143 | U1L1-41200R-20212K-S | 4 x 4.0 | 1.0 | 1.25 | 1.8 | 20 | 825 | 1000 |
L144 | U1L1-41300R-20212K-S | 4 x 6.0 | 1.0 | 1.25 | 1.8 | 21 | 975 | 1000 |
L145 | U1L1-41400R-20212K-S | 4 x 10 | 1.0 | 1.25 | 1.8 | 23 | 1225 | 1000 |
L146 | U1L1-41500R-20212K-S | 4 x 16 | 1.0 | 1.60 | 1.8 | 26 | 1725 | 1000 |
L147 | U1L1-41600S-20212K-S | 4 x 25 | 1.2 | 1.60 | 1.8 | 28 | 2075 | 1000 |
L148 | U1L1-41700S-20212K-S | 4 x 35 | 1.2 | 1.60 | 1.9 | 30 | 2575 | 1000 |
L149 | U1L1-41800S-20212K-S | 4 x 50 | 1.4 | 2.00 | 2.1 | 36 | 3575 | 500 |
L150 | U1L1-41900S-20212K-S | 4 x 70 | 1.4 | 2.00 | 2.2 | 39 | 4600 | 500 |
L151 | U1L1-42000S-20212K-S | 4 x 95 | 1.6 | 2.50 | 2.4 | 45 | 6375 | 500 |
L152 | U1L1-42100S-20212K-S | 4 x 120 | 1.6 | 2.50 | 2.5 | 49 | 7525 | 500 |
L153 | U1L1-42200S-20212K-S | 4 x 150 | 1.8 | 2.50 | 2.7 | 54 | 9050 | 250 |
L154 | U1L1-42300S-20212K-S | 4 x 185 | 2.0 | 2.50 | 2.9 | 59 | 10900 | 250 |
L155 | U1L1-42400S-20212K-S | 4 x 240 | 2.2 | 2.50 | 3.1 | 65 | 13600 | 250 |
L156 | U1L1-42500S-20212K-S | 4 x 300 | 2.4 | 2.50 | 3.3 | 71 | 16525 | 250 |
Order No. | Item Code No. | Nominal Area | Nominal Insulation Thickness | Nominal Steel Tape Thickness | Nominal Outer Sheath Thickness | Approx. Overall Diameter* | Approx. Cable Weight** | Standard Length |
No. x mm2 | mm | mm | mm | mm | Kg/Km | (mtr. ± 5%) | ||
L157 | U1L1-50800R-20212K-S | 5 x 1.5 | 0.8 | 0.90 | 1.8 | 16 | 525 | 1000 |
L158 | U1L1-51000R-20212K-S | 5 x 2.5 | 0.8 | 0.90 | 1.8 | 18 | 630 | 1000 |
L159 | U1L1-51200R-20212K-S | 5 x 4.0 | 1.0 | 1.25 | 1.8 | 21 | 925 | 1000 |
L160 | U1L1-51300R-20212K-S | 5 x 6.0 | 1.0 | 1.25 | 1.8 | 22 | 1125 | 1000 |
L161 | U1L1-51400R-20212K-S | 5 x 10 | 1.0 | 1.60 | 1.8 | 26 | 1575 | 1000 |
L162 | U1L1-51500R-20212K-S | 5 x 16 | 1.0 | 1.60 | 1.8 | 28 | 2050 | 1000 |
L163 | U1L1-51600C-20212K-S | 5 x 25 | 1.2 | 1.60 | 1.9 | 32 | 2725 | 500 |
L164 | U1L1-51700C-20212K-S | 5 x 35 | 1.2 | 2.00 | 2.0 | 36 | 3700 | 500 |
L165 | U1L1-51800C-20212K-S | 5 x 50 | 1.4 | 2.00 | 2.2 | 42 | 4800 | 500 |
L166 | U1L1-51900C-20212K-S | 5 x 70 | 1.4 | 2.00 | 2.3 | 46 | 6100 | 500 |
Copper conductor XLPE Insulated Cable (Unarmoured)
L221 | U1L1-11400R-10002K-S | 1 x 10 | 0.7 | 1.4 | 8.3 | 146 | 1000 |
L222 | U1L1-11500R-10002K-S | 1 x 16 | 0.7 | 1.4 | 9.3 | 206 | 1000 |
L223 | U1L1-11600C-10002K-S | 1 x 25 | 0.9 | 1.4 | 10.6 | 300 | 1000 |
L224 | U1L1-11700C-10002K-S | 1 x 35 | 0.9 | 1.4 | 11.7 | 402 | 1000 |
L225 | U1L1-11800C-10002K-S | 1 x 50 | 1.0 | 1.4 | 13.2 | 530 | 1000 |
L226 | U1L1-11900C-10002K-S | 1 x 70 | 1.1 | 1.4 | 15.0 | 731 | 1000 |
L227 | U1L1-12000C-10002K-S | 1 x 95 | 1.1 | 1.5 | 16.8 | 996 | 1000 |
L228 | U1L1-12100C-10002K-S | 1 x 120 | 1.2 | 1.5 | 18.5 | 1225 | 1000 |
L229 | U1L1-12200C-10002K-S | 1 x 150 | 1.4 | 1.6 | 20.6 | 1537 | 1000 |
L230 | U1L1-12300C-10002K-S | 1 x 185 | 1.6 | 1.6 | 22.6 | 1888 | 1000 |
L231 | U1L1-12400C-10002K-S | 1 x 240 | 1.7 | 1.7 | 25.3 | 2466 | 1000 |
L232 | U1L1-12500C-10002K-S | 1 x 300 | 1.8 | 1.8 | 27.8 | 3040 | 500 |
L233 | U1L1-12600C-10002K-S | 1 x 400 | 2.0 | 1.9 | 31.6 | 3870 | 500 |
L234 | U1L1-12700C-10002K-S | 1 x 500 | 2.2 | 2.0 | 35.0 | 4892 | 500 |
L235 | U1L1-12900C-10002K-S | 1 x 630 | 2.4 | 2.2 | 39.1 | 6215 | 500 |
Copper Conductor XLPE Insulated Cable (Armoured)
L306 | U1L1-11800C-10222K-S | 1 x 50 | 1.0 | 1.25 | 1.8 | 19 | 775 | 1000 |
L307 | U1L1-11900C-10222K-S | 1 x 70 | 1.1 | 1.25 | 1.8 | 21 | 1025 | 1000 |
L308 | U1L1-12000C-10222K-S | 1 x 95 | 1.1 | 1.25 | 1.8 | 22 | 1300 | 1000 |
L309 | U1L1-12100C-10222K-S | 1 x 120 | 1.2 | 1.60 | 1.8 | 25 | 1600 | 1000 |
L310 | U1L1-12200C-10222K-S | 1 x 150 | 1.4 | 1.60 | 1.8 | 27 | 1950 | 1000 |
L311 | U1L1-12300C-10222K-S | 1 x 185 | 1.6 | 1.60 | 1.8 | 29 | 2350 | 1000 |
L312 | U1L1-12400C-10222K-S | 1 x 240 | 1.7 | 1.60 | 1.9 | 31 | 2950 | 500 |
L313 | U1L1-12500C-10222K-S | 1 x 300 | 1.8 | 1.60 | 1.9 | 34 | 3550 | 500 |
L314 | U1L1-12600C-10222K-S | 1 x 400 | 2.0 | 2.00 | 2.1 | 39 | 4600 | 500 |
L315 | U1L1-12700C-10222K-S | 1 x 500 | 2.2 | 2.00 | 2.2 | 42 | 5700 | 500 |
L316 | U1L1-12900C-10222K-S | 1 x 630 | 2.4 | 2.00 | 2.3 | 46 | 7100 | 500 |
ABC Cables
NFC 33209 0.6/1 kV Aerial bundled Cable ABC Cable
NFC 33209 0.6/1kV Aerial bundle Cable ABC Cable XLPE Insulated Cable
ABC Cable Application
NFC 33209 0.6/1kV Aerial bundle Cable ABC Cable XLPE Insulated Cable is the overhead insulated cable, used as public lighting wire or testing wire etc.
Aerial bunched cable 0.6/1kV is extensively installed in urban and forest region which provides the safety and reliance for public power distribution network.
ABC Cable Characteristics
Rated Voltage Uo/U (Um) :0.6/1kV (1.2kV)
Temperature Rating: Operation temp.:90℃; Short Circuit Temp.:250℃
Minimum Bending Radius:Single core: 13×OD; Multi-core: 6×OD(min) while 12×OD during installation
ABC Cable Construction
Aerial Bundle Conductor(ABC)
Aerial Bundled Conductors (Phase Core): Circular, Class 2 stranded conductor, round compacted or non-compacted AAC conductor, AAAC conductor, or ACSR.
Aerial Bundled Conductor Messenger or Neutral Core:Circular, Class 2 stranded conductor, round compacted or non-compacted AAAC conductor (All Aluminium Alloy Conductor), AAC conductor(all aluminium conductor); ACSR conductor(Aluminium Conductor Steel Reinforced conductor),
Neutral Core Sizes: 54.6mm2, 70mm2, 95mm2
ABC Conductor Lighting Conductor:Circular, Class 2 stranded conductor, round compacted or non-compacted AAC conductor, AAAC conductor, or ACSR
Aluminium conductors ABC standard as per NF C 32-013, IEC 228 & IEC 228A
LV Aerial Bundled Cable Insulation
Overhead Conductor (ABC) Insulation: Low Density Polyethylene (LDPE), High Density Polyethylene(HDPE), XLPE(cross-linked polyethylene ), Polyvinyl chloride(PVC).
Aerial Bunch Cable Standard
As one of leading ABC Cable suppliers, we produce aerial bunched cables meeting NFC 33029, IEC60228, NF C 32-013,NFC 32 013, AS/NZS 3560.1,BS 7870-5,ANSI/CEA S-76-474,NTP 370.254 etc
Low Voltage Aerial Bundle Cables Specification
Aerial Bundled Cable Size Without Messenger As Following:
* 2 x 16 mm2 * 2 x 16 mm2 + 2 x 1.5 mm2
* 2 x 25 mm2 * 2 x 25 mm2 + 2 x 1.5 mm2
2 x 35 mm2 2 x 35 mm2 + 2 x 1.5 mm2
2 x 50 mm2 2 x 50 mm2 + 2 x 1.5 mm2
* 4 x 16 mm2 * 4 x 16 mm2 + 2 x 1.5 mm2
4 x 25 mm2 * 4 x 25 mm2 + 2 x 1.5 mm2
4 x 35 mm2 4 x 35 mm2 + 2 x 1.5 mm2
LV Aerial Bundled Cable With Messenger Construction As Following:
1 x 54.6 mm2 + 3 x 25 mm2 + K x 16 mm2
* 1 x 54.6 mm2 + 3 x 35 mm2 + K x 16 mm2
1 x 54.6 mm2 + 3 x 50 mm2 + K x 16 mm2
1 x 54.6 mm2 + 3 x 70 mm2 + K x 16 mm2
1 x 54.6 mm2 + 3 x 70 mm2 + K x 25 mm2
* 1 x 70 mm2+ 3 x 70 mm2+ K x 16 mm2
1 x 70 mm2+ 3 x 95 mm2+ K x 16 mm2
1 x 70 mm2+ 3 x 120 mm2 + K x 16 mm2
* 1 x 70 mm2+ 3 x 120 mm2+ K x 16 mm2
1 x 95 mm2+ 3 x 120 mm2+ K x 16 mm2
1 x 95 mm2+ 3 x 150 mm2+ K x 16 mm2
Remark: K represents number of lighting core, which could be 0 core, 1 core,2 cores,3cores.
Aerial Insulated Cable Technical Data
Name | Conductor | Average Thickness of Insulation | Lighting Wire | ||||||
Category | Norm Cross-Section | No. Of Strand | DC Resistance | Conductor Diameter | Breaking Load | Overall Diameter | |||
(mm2) | 20℃ (Ω/km) | Min (mm) | Max (mm) | Min (daN) | (mm) | Min (mm) | Maz (mm) | ||
Phase Core, neutral core(not messenger) or lighting core | 16 25 35 50 70 95 120 150 | 7 7 7 7 12 19 19 19 | 1.91 1.20 0.868 0.641 0.443 0.320 0.253 0.206 | 4.6 5.8 6.8 7.9 9.7 11.0 12.0 13.9 | 5.1 6.3 7.3 8.4 10.2 12.0 13.1 15.0 | 190 300 – – – – – – | 1.2 1.4 1.6 1.6 1.8 1.8 1.8 1.7 | 7.0 8.6 10.0 11.1 13.3 14.6 15.6 17.3 | 7.8 9.4 10.9 12.0 14.2 15.7 16.7 18.6 |
Messenger | 54.6 70 95 | 7 7 19 | 0.63 0.50 0.343 | 9.2 10.0 12.2 | 9.6 10.2 12.9 | 1660 2050 2750 | 1.6 1.5 1.6 | 12.3 12.9 15.3** | 13.0 13.6 16.3** |
1KV XLPE Insulation Overhead Cable Markings
Embossed, gravure or ink printed
Core Identification of Overhead Cable ABC cable
By Color Strip; By Number, By Rib.