<?xml version="1.0"?>
<oembed><version>1.0</version><provider_name>Wadi Al Seer Cables</provider_name><provider_url>https://wadiseercables.com/ar</provider_url><author_name>wadiseercables</author_name><author_url>https://wadiseercables.com/ar/author/wadiseercables/</author_url><title>Domestic Wires | Wadi Al Seer Cables</title><type>rich</type><width>600</width><height>338</height><html>&lt;blockquote class="wp-embedded-content" data-secret="Bie59j1lSS"&gt;&lt;a href="https://wadiseercables.com/ar/domestic-wires/"&gt;&#x627;&#x644;&#x623;&#x633;&#x644;&#x627;&#x643; &#x627;&#x644;&#x645;&#x646;&#x632;&#x644;&#x64A;&#x629;&lt;/a&gt;&lt;/blockquote&gt;&lt;iframe sandbox="allow-scripts" security="restricted" src="https://wadiseercables.com/ar/domestic-wires/embed/#?secret=Bie59j1lSS" width="600" height="338" title="&#x201C;Domestic Wires&#x201D; &#x2014; Wadi Al Seer Cables" data-secret="Bie59j1lSS" frameborder="0" marginwidth="0" marginheight="0" scrolling="no" class="wp-embedded-content"&gt;&lt;/iframe&gt;&lt;script&gt;
/*! This file is auto-generated */
!function(d,l){"use strict";l.querySelector&amp;&amp;d.addEventListener&amp;&amp;"undefined"!=typeof URL&amp;&amp;(d.wp=d.wp||{},d.wp.receiveEmbedMessage||(d.wp.receiveEmbedMessage=function(e){var t=e.data;if((t||t.secret||t.message||t.value)&amp;&amp;!/[^a-zA-Z0-9]/.test(t.secret)){for(var s,r,n,a=l.querySelectorAll('iframe[data-secret="'+t.secret+'"]'),o=l.querySelectorAll('blockquote[data-secret="'+t.secret+'"]'),c=new RegExp("^https?:$","i"),i=0;i&lt;o.length;i++)o[i].style.display="none";for(i=0;i&lt;a.length;i++)s=a[i],e.source===s.contentWindow&amp;&amp;(s.removeAttribute("style"),"height"===t.message?(1e3&lt;(r=parseInt(t.value,10))?r=1e3:~~r&lt;200&amp;&amp;(r=200),s.height=r):"link"===t.message&amp;&amp;(r=new URL(s.getAttribute("src")),n=new URL(t.value),c.test(n.protocol))&amp;&amp;n.host===r.host&amp;&amp;l.activeElement===s&amp;&amp;(d.top.location.href=t.value))}},d.addEventListener("message",d.wp.receiveEmbedMessage,!1),l.addEventListener("DOMContentLoaded",function(){for(var e,t,s=l.querySelectorAll("iframe.wp-embedded-content"),r=0;r&lt;s.length;r++)(t=(e=s[r]).getAttribute("data-secret"))||(t=Math.random().toString(36).substring(2,12),e.src+="#?secret="+t,e.setAttribute("data-secret",t)),e.contentWindow.postMessage({message:"ready",secret:t},"*")},!1)))}(window,document);
//# sourceURL=https://wadiseercables.com/wp-includes/js/wp-embed.min.js
&lt;/script&gt;</html><description>Domestic wires are made to meet BS, IEC, and UL regulations, with a rated voltage of up to 450/750 volts.These cables are used for internal siminsagh wiring in structures and electrical equipment.They are appropriate for both fixed and transportable interior installations. 300/500 Volts &#x2013; Copper Conductor PVC Insulated Standard: BS 6004 Conductor: Class 1 solid copper, class 2 stranded copper or class 5 flexible copper as per IEC 60228, BS EN 60228 Rated Voltage: 300/500 V Insulation: PVC Insulation type TI1 as per BS EN 50363,PVC/C as per IEC 60227temperature rating 70 &#xBA;C.(PVC 90 &#xBA;C or 105 &#xBA;C available on request). Harmonized Code: Solid conductor&nbsp;HO5V-UStranded conductor&nbsp;HO5V-RFlexible conductor&nbsp;HO5V-K Applications: Fixed protected installation inside the appliances and in or on light fitting. Type of Conductor Order No. Item Code No. Nominal Area Insulation Thickness Approx. Overall Diameter * Approx Weight ** Standard Length Standard Packing mm&#xB2; mm mm kg/km m tr. Solid T001 U1T2-10400E-20000x-4 0.5 0.6 2.0 9.0 91.4 Coil T002 U1T2-10500E-20000x-4 0.75 0.6 2.2 12.0 91.4 Coil T003 U1T2-10600E-20000x-4 1.0 0.6 2.4 14.0 91.4 Coil Stranded T004 U1T2-10400R-20000x-4 0.5 0.6 2.2 11.0 91.4 Coil T005 U1T2-10500R-20000x-4 0.75 0.6 2.4 13.0 91.4 Coil T006 U1T2-10600R-20000x-4 1.0 0.6 2.6 15.0 91.4 Coil Flexible T007 U1T2-10400F-20000x-4 0.5 0.6 2.1 10.0 91.4 Coil T008 U1T2-10500F-20000x-4 0.75 0.6 2.3 12.0 91.4 Coil T009 U1T2-10600F-20000x-4 1.0 0.6 2.5 14.0 91.4 Coil Features: 450/750 Volts &#x2013; Copper Conductor PVC Insulated Standard: BS 6004, IEC 60227 Conductor: Class 1 solid copper, class 2 stranded copper as per IEC 60228, BS EN 60228. Rated Voltage: 450/750 V Insulation: PVC Insulation type TI1 as per BS EN 50363,PVC/C as per IEC 60227temperature rating 70 &#xBA;C.(PVC 90 &#xBA;C or 105 &#xBA;C available on request). Harmonized Code: Solid conductor&nbsp;HO7V-UStranded conductor&nbsp;HO7V-R Applications: Fixed installation in dry or damp premises. Suitabel in walls or boards and in channel or embadded in plaster. Type of Conductor Order No. Item Code No. Nominal Area Insulation Thickness Approx. Overall Diameter * Approx Weight ** Standard Length Standard Packing mm&#xB2; mm mm kg/km m tr. Solid W001 U1W2-10800E-20000x-4 1.5 0.7 2.8 21.1 91.4 Coil W002 U1W2-11000E-20000x-4 2.5 0.8 3.4 33.1 91.4 Coil W003 U1W2-11200E-20000x-4 4 0.8 3.9 47.0 91.4 Coil W004 U1W2-11300E-20000x-4 6 0.8 4.4 65.0 91.4 Coil W005 U1W2-11400E-20000x-4 10 1.0 5.6 107.0 91.4 Coil Stranded W006 U1W2-10800R-20000x-4 1.5 0.7 3.0 21.0 91.4 Coil W007 U1W2-11000R-20000x-4 2.5 0.8 3.6 34.0 91.4 Coil W008 U1W2-11200R-20000x-4 4 0.8 4.2 48.0 91.4 Coil W009 U1W2-11300R-20000x-4 6 0.8 4.7 68.0 91.4 Coil W0010 U1W2-11400R-20000x-4 10 1.0 6.1 112.0 91.4 Coil W0011 U1W2-11500R-20000x-4 16 1.0 7.1&nbsp; 169.0 91.4 Coil W0012 U1W2-11600C-20000x-4 25 1.2 8.4 260.0 91.4 Coil W0013 U1W2-11700C-20000x-4 35 1.2&nbsp; 9.4 355.0 91.4 Coil W0014 U1W2-11800C-20000x-A 50 1.4 10.9 480.0 1000 Drum W0015 U1W2-11900C-20000x-A 70 1.4 12.5&nbsp; 670.0 1000 Drum W0016 U1W2-12000C-20000x-A 95 1.6 14.6 935.0 1000 Drum W0017 U1W2-12100C-20000x-A 120 1.6 16.1&nbsp; 1155.0 1000 Drum W0018 U1W2-12200C-20000x-A 150 1.8 17.9 1455.0 1000 Drum W0019 U1W2-12300C-20000x-A 185 2.0&nbsp; 20.0 1800.0 1000 Drum W0020 U1W2-12400C-20000x-A 240 2.2 22.8 2355.0 1000 Drum W0021 U1W2-12500C-20000x-A 300 2.4 25.2 2945.0 1000 Drum W0022 U1W2-12600C-20000x-9 400 2.6 28.4 3745.0 500 Drum W0023 U1W2-12700C-20000x-9 500 2.8 32.3 4755.0 500 Drum W0024 U1W2-12900C-20000x-9 630 2.8 36.0 6025.0 500 Drum Features: Standard: BS 6004, IEC 60227 Conductor: Class 5 flexible copper as per IEC 60228,BS EN 60228. Rated Voltage: 450/750 V Insulation: PVC Insulation type TI1 as per BS EN 50363,PVC/C as per IEC 60227temperature rating 70 &#xBA;C.(PVC 90 &#xBA;C or 105 &#xBA;C available on request). Harmonized Code: Flexible conductor&nbsp;HO7V-K Applications: Suitable for use in channels with cover and for fixed protected installation in or on light fittings and inside applicances, switchgear and controlgear for voltages up to 1000V a.c. or up to 750V d.c. to earth. Order No. Item Code No. Nominal Area Insulation Thickness Approx. Overall Diameter * Approx Weight ** Standard Length Standard Packing mm&#xB2; mm mm kg/km m tr. W025 U1W2-10800F-20000x-4 1.5 0.7 3.0 21.0 91.4 Coil W026 U1W2-11000F-20000x-4 2.5 0.8 3.5 32.0 91.4 Coil W027 U1W2-11200F-20000x-4 4 0.8 4.1 48.0 91.4 Coil W028 U1W2-11300F-20000x-4 6 0.8 4.7 68.0 91.4 Coil W029 U1W2-11400F-20000x-4 10 1.0 5.9 115.0 91.4 Coil W030 U1W2-11500F-20000x-4 16 1.0 6.9 167.0 91.4 Coil W031 U1W2-11600F-20000x-4 25 1.2 8.9 255.0 91.4 Coil W032 U1W2-11700F-20000x-4 35 1.2 10.4 360.0 91.4 Coil W033 U1W2-11800F-20000x-A 50 1.4 12.0 495.0 1000 Drum W034 U1W2-11900F-20000x-A 70 1.4 13.8 685.0 1000 Drum W035 U1W2-12000F-20000x-A 95 1.6 15.8 900.0 1000 Drum W036 U1W2-12100F-20000x-A&nbsp; 120 1.6 17.3 1115.0 1000 Drum W037 U1W2-12200F-20000x-A 150 1.8 20.1 1415.0 1000 Drum W038 U1W2-12300F-20000x-A 185 2.0 21.8 1800.0 1000 Drum W039 U1W2-12400F-20000x-A 240 2.2 24.8 2320.0&nbsp; 1000 Drum Features: 300/500 Volts &#x2013; PVC Insulated PVC Sheathed Flat Cables Standard: BS 6004 Conductor: Class 1 solid copper, class 2 stranded copper as per IEC 60228, BS EN 60228. Rated Voltage: 300/500 V Insulation: PVC Insulation type TI1 as per BS EN 50363.PVC type 6 as per BS EN 50363(PVC 90 &#xBA;C or 105 &#xBA;C available on request). Harmonized Code: Flexible conductor&nbsp;HO7V-K Applications: Fixed installation in dry or damp premises. Suitable for installation in walls, on boards and in channels or embedded in plaster. Order No. &nbsp;&nbsp;Item Code No. Nominal Area Insulation Thickness Nominal Sheath Thickness Approx. Overall Dimensions * Approx Weight ** Standard Length Standard Packing No. x mm2 mm mm mm Kg/Km mtr T010 U1T2-20600R-20002D-4 2 x 1.0 0.6 0.9 4.4 x 6.9 53.0 91.4 Coil&nbsp; T011&nbsp; U1T2-20800R-20002D-4 2 x 1.5 0.7 0.9 4.8 x 7.8 70.0 91.4 Coil&nbsp; T012 U1T2-21000R-20002D-4 2 x 2.5 0.8 1.0 5.6 x 9.2 104.0 91.4 Coil&nbsp; T013 U1T2-21200R-20002D-4 2 x 4.0 0.8 1.0 6.2 x 10.3 140.0 91.4 Coil&nbsp; T014 U1T2-21300R-20002D-4 2 x 6.0 0.8 1.0 7.0 x 11.7 191.0 91.4 Coil&nbsp; T015 U1T2-21400R-20002D-4 2 x 10 1.0 1.2 8.5 x 14.5 303.0 91.4 Coil&nbsp; T016 U1T2-30600R-20002D-4 3 x 1.0 0.6 0.9 4.4 x 9.4 76.0 91.4 Coil&nbsp; T017 U1T2-30800R-20002D-4 3 x 1.5 0.7 0.9 4.8 x 10.8 102.0 91.4 Coil&nbsp; T018 U1T2-31000R-20002D-4 3 x 2.5 0.8 1.0 5.6 x 12.8 149.0 91.4 Coil&nbsp; T019 U1T2-31200R-20002D-4 3 x</description></oembed>
