{"id":1787,"date":"2025-02-04T07:51:26","date_gmt":"2025-02-04T07:51:26","guid":{"rendered":"https:\/\/wadiseercables.com\/?p=1787"},"modified":"2025-02-04T08:06:32","modified_gmt":"2025-02-04T08:06:32","slug":"low-voltage-power-cables","status":"publish","type":"post","link":"https:\/\/wadiseercables.com\/ar\/low-voltage-power-cables\/","title":{"rendered":"Low Voltage Power Cables"},"content":{"rendered":"<p>Low voltage power cables are built to IEC and BS requirements, with a rated voltage of 0.6\/1KV.<br>These cables are used to distribute electricity in metropolitan networks, industrial facilities, and electrical machinery.<br>They are excellent for both indoor and outdoor applications, as well as moist and wet environments.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">\u0643\u0627\u0628\u0644\u0627\u062a \u0646\u062d\u0627\u0633\u064a\u0629 \u0645\u0639\u0632\u0648\u0644\u0629 \u0628\u0640 PVC (\u063a\u064a\u0631 \u0645\u0633\u0644\u062d)<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>PVC Insulated, PVC Sheathed Unarmoured Cables CU \/ PVC \/ PVC Single Core<\/strong><\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td><strong>Standard<\/strong>:<\/td><td>IEC 60502-1<\/td><td><strong>Conductor<\/strong>:<\/td><td>Class 2 stranded copper as per IEC 60228, BS EN 60228.<\/td><\/tr><tr><td><strong>Rated Voltage:<\/strong><\/td><td>0.6\/1 KV<\/td><td><strong>Insulation:<\/strong><\/td><td>PVC insulation type A as per IEC 60502-1 or type TI1 as per BS EN 50363<br>temperature rating 70 oC.<br>(PVC 90 oC is available on request).<\/td><\/tr><tr><td><strong>Shape of Conductor:<\/strong><\/td><td>16 mm2 and below, conductor shall be circular stranded non-compacted.<br>25 mm2 and above, conductor shall be circular stranded compacted.<\/td><td><strong>Outer Sheath:<\/strong><\/td><td>PVC outer sheath type ST1 as per IEC 60502-1 or type TM1 as per BS EN 50363.<\/td><\/tr><tr><td><\/td><td><\/td><td><strong>Applications:<\/strong><\/td><td>For outdoor and indoor installations in damp and wet locations. They are normally used for power distribution in urban networks, industrial plants and energy distribution.<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td rowspan=\"2\"><strong>Order No.<\/strong><\/td><td rowspan=\"2\"><strong>Item Code No.<\/strong><\/td><td><strong>Nominal Area<\/strong><\/td><td><strong>Nominal Insulation Thickness<\/strong><\/td><td><strong>Nominal Outer Sheath Thickness<\/strong><\/td><td><strong>Approx. Overall Diameter*&nbsp;<\/strong><\/td><td><strong>Approx. Cable Weight**&nbsp;<\/strong><\/td><td><strong>Standard Length<\/strong><\/td><\/tr><tr><td>No. x mm2<\/td><td>mm<\/td><td>mm<\/td><td>mm<\/td><td>Kg\/Km<\/td><td>(mtr. \u00b1 5%)<\/td><\/tr><tr><td><strong>L001<\/strong><\/td><td>U1L1-11400R-20002K-S<\/td><td>1 x 10<\/td><td>1.0<\/td><td>1.4<\/td><td>9<\/td><td>175<\/td><td>1000<\/td><\/tr><tr><td><strong>L002<\/strong><\/td><td>U1L1-11500R-20002K-S<\/td><td>1 x 16<\/td><td>1.0<\/td><td>1.4<\/td><td>10<\/td><td>235<\/td><td>1000<\/td><\/tr><tr><td><strong>L003<\/strong><\/td><td>U1L1-11600C-20002K-S<\/td><td>1 x 25<\/td><td>1.2<\/td><td>1.4<\/td><td>12<\/td><td>330<\/td><td>1000<\/td><\/tr><tr><td><strong>L004<\/strong><\/td><td>U1L1-11700C-20002K-S<\/td><td>1 x 35<\/td><td>1.2<\/td><td>1.4<\/td><td>13<\/td><td>430<\/td><td>1000<\/td><\/tr><tr><td><strong>L005<\/strong><\/td><td>U1L1-11800C-20002K-S<\/td><td>1 x 50<\/td><td>1.4<\/td><td>1.4<\/td><td>14<\/td><td>575<\/td><td>1000<\/td><\/tr><tr><td><strong>L006<\/strong><\/td><td>U1L1-11900C-20002K-S<\/td><td>1 x 70<\/td><td>1.4<\/td><td>1.4<\/td><td>16<\/td><td>775<\/td><td>1000<\/td><\/tr><tr><td><strong>L007<\/strong><\/td><td>U1L1-12000C-20002K-S<\/td><td>1 x 95<\/td><td>1.6<\/td><td>1.5<\/td><td>18<\/td><td>1050<\/td><td>1000<\/td><\/tr><tr><td><strong>L008<\/strong><\/td><td>U1L1-12100C-20002K-S<\/td><td>1 x 120<\/td><td>1.6<\/td><td>1.5<\/td><td>20<\/td><td>1300<\/td><td>1000<\/td><\/tr><tr><td><strong>L009<\/strong><\/td><td>U1L1-12200C-20002K-S<\/td><td>1 x 150<\/td><td>1.8<\/td><td>1.6<\/td><td>22<\/td><td>1575<\/td><td>1000<\/td><\/tr><tr><td><strong>L010<\/strong><\/td><td>U1L1-12200C-20002K-S<\/td><td>1 x 185<\/td><td>2.0<\/td><td>1.7<\/td><td>24<\/td><td>1975<\/td><td>1000<\/td><\/tr><tr><td><strong>L011<\/strong><\/td><td>U1L1-12400C-20002K-S<\/td><td>1 x 240<\/td><td>2.2<\/td><td>1.8<\/td><td>27<\/td><td>2550<\/td><td>1000<\/td><\/tr><tr><td><strong>L012<\/strong><\/td><td>U1L1-12500C-20002K-S<\/td><td>1 x 300<\/td><td>2.4<\/td><td>1.9<\/td><td>30<\/td><td>3175&nbsp;<\/td><td>1000<\/td><\/tr><tr><td><strong>L013<\/strong><\/td><td>U1L1-12600C-20002K-S<\/td><td>1 x 400<\/td><td>2.6<\/td><td>2.0<\/td><td>33<\/td><td>4025<\/td><td>500<\/td><\/tr><tr><td><strong>L014<\/strong><\/td><td>U1L1-12700C-20002K-S<\/td><td>1 x 500<\/td><td>2.8<\/td><td>2.1<\/td><td>37<\/td><td>5100<\/td><td>500<\/td><\/tr><tr><td><strong>L015<\/strong><\/td><td>U1L1-12900C-20002K-S<\/td><td>1 x 630<\/td><td>2.8<\/td><td>2.2<\/td><td>41<\/td><td>6475<\/td><td>500<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>PVC Insulated, PVC Sheathed Unarmoured Cables CU \/ PVC \/ PVC Two Core<\/strong><\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td><strong>Standard<\/strong>:<\/td><td>IEC 60502-1<\/td><td><strong>Conductor<\/strong>:<\/td><td>Class 1 solid (up to 6 mm2<br>upon request) copper or class 2 stranded copper as per IEC 60228,<br>BS EN 60228.<\/td><\/tr><tr><td><strong>Rated Voltage:<\/strong><\/td><td>0.6\/1 KV<\/td><td><strong>Insulation:<\/strong><\/td><td>PVC insulation type A as per IEC 60502-1 or type TI1 as per BS EN 50363<br>temperature rating 70 oC.<br>(PVC 90 oC is available on request).<\/td><\/tr><tr><td><strong>Shape of Conductor:<\/strong><\/td><td>16 mm2 and below, conductor shall be circular stranded non-compacted.<br>25 mm2 and above, conductor shall be circular stranded compacted.<\/td><td><strong>Outer Sheath:<\/strong><\/td><td>PVC outer sheath type ST1 as per IEC 60502-1 or type TM1 as per BS EN 50363.<\/td><\/tr><tr><td><\/td><td><\/td><td><strong>Applications:<\/strong><\/td><td>For outdoor and indoor installations in damp and wet locations. They are normally used for power distribution in urban networks, industrial plants and energy distribution.<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td rowspan=\"2\">Order No.<\/td><td rowspan=\"2\">Item Code No.<\/td><td>Nominal Area<\/td><td>Nominal Insulation Thickness<\/td><td>Nominal Outer Sheath Thickness<\/td><td>Approx. Overall Diameter*&nbsp;<\/td><td>Approx. Cable Weight**&nbsp;<\/td><td>Standard Length<\/td><\/tr><tr><td>No. x mm2<\/td><td>mm<\/td><td>mm<\/td><td>mm<\/td><td>Kg\/Km<\/td><td>(mtr. \u00b1 5%)<\/td><\/tr><tr><td>L016<\/td><td>U1L1-20800R-20002K-S<\/td><td>2 x 1.5&nbsp;<\/td><td>0.8<\/td><td>1.8<\/td><td>10<\/td><td>150<\/td><td>1000<\/td><\/tr><tr><td>L017<\/td><td>U1L1-21000R-20002K-S<\/td><td>2 x 2.5<\/td><td>0.8<\/td><td>1.8<\/td><td>11<\/td><td>190<\/td><td>1000<\/td><\/tr><tr><td>L018<\/td><td>U1L1-21200R-20002K-S<\/td><td>2 x 4.0<\/td><td>1.0<\/td><td>1.8<\/td><td>13<\/td><td>260<\/td><td>1000<\/td><\/tr><tr><td>L019<\/td><td>U1L1-21300R-20002K-S<\/td><td>2 x 6.0<\/td><td>1.0<\/td><td>1.8<\/td><td>14<\/td><td>330<\/td><td>1000<\/td><\/tr><tr><td>L020<\/td><td>U1L1-21400R-20R02K-S<\/td><td>2 x 10<\/td><td>1.0<\/td><td>1.8<\/td><td>18<\/td><td>575<\/td><td>1000<\/td><\/tr><tr><td>L021<\/td><td>U1L1-21500R-20R02K-S<\/td><td>2 x 16<\/td><td>1.0<\/td><td>1.8<\/td><td>20<\/td><td>760<\/td><td>1000<\/td><\/tr><tr><td>L022<\/td><td>U1L1-21600C-20202K-S<\/td><td>2 x 25<\/td><td>1.2<\/td><td>1.8<\/td><td>23<\/td><td>975<\/td><td>1000<\/td><\/tr><tr><td>L023<\/td><td>U1L1-21700C-20202K-S<\/td><td>2 x 35<\/td><td>1.2<\/td><td>1.8<\/td><td>25<\/td><td>1250<\/td><td>1000<\/td><\/tr><tr><td>L024<\/td><td>U1L1-21800C-20202K-S<\/td><td>2 x 50<\/td><td>1.4<\/td><td>1.8<\/td><td>29<\/td><td>1650<\/td><td>1000<\/td><\/tr><tr><td>L025<\/td><td>U1L1-21900C-20202K-S<\/td><td>2 x 70<\/td><td>1.4<\/td><td>1.9<\/td><td>32<\/td><td>2225<\/td><td>500<\/td><\/tr><tr><td>L026<\/td><td>U1L1-22000C-20202K-S<\/td><td>2 x 95<\/td><td>1.6<\/td><td>2.0<\/td><td>37<\/td><td>2975<\/td><td>500<\/td><\/tr><tr><td>L027<\/td><td>U1L1-22100C-20202K-S<\/td><td>2 x 120<\/td><td>1.6<\/td><td>2.1<\/td><td>40<\/td><td>3575<\/td><td>500<\/td><\/tr><tr><td>L028<\/td><td>U1L1-22200C-20202K-S<\/td><td>2 x 150<\/td><td>1.8<\/td><td>2.2<\/td><td>44<\/td><td>4475<\/td><td>500<\/td><\/tr><tr><td>L029<\/td><td>U1L1-22300C-20202K-S<\/td><td>2 x 185<\/td><td>2.0<\/td><td>2.4<\/td><td>48<\/td><td>5475<\/td><td>500<\/td><\/tr><tr><td>L030<\/td><td>U1L1-22400C-20202K-S<\/td><td>2 x 240<\/td><td>2.2<\/td><td>2.6<\/td><td>55<\/td><td>7100<\/td><td>250<\/td><\/tr><tr><td>L031<\/td><td>U1L1-22500C-20202K-S<\/td><td>2 x 300<\/td><td>2.4<\/td><td>2.7<\/td><td>60<\/td><td>8700<\/td><td>250<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>PVC Insulated, PVC Sheathed Unarmoured Cables CU \/ PVC \/ PVC Three Core<\/strong><\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td><strong>Standard<\/strong>:<\/td><td>IEC 60502-1<\/td><td><strong>Conductor<\/strong>:<\/td><td>Class 1 solid (up to 6 mm2<br>upon request) copper or class 2 stranded copper as per IEC 60228,<br>BS EN 60228.<\/td><\/tr><tr><td><strong>Rated Voltage:<\/strong><\/td><td>0.6\/1 KV<\/td><td><strong>Insulation:<\/strong><\/td><td>PVC insulation type A as per IEC 60502-1 or type TI1 as per BS EN 50363<br>temperature rating 70 oC.<br>(PVC 90 oC is available on request).<\/td><\/tr><tr><td><strong>Shape of Conductor:<\/strong><\/td><td>16 mm2 and below, conductor shall be circular stranded non-compacted.<br>25 mm2 and above, conductor shall be sectoral stranded compacted.<\/td><td><strong>Outer Sheath:<\/strong><\/td><td>PVC outer sheath type ST1 as per IEC 60502-1 or type TM1 as per BS EN 50363.<\/td><\/tr><tr><td><\/td><td><\/td><td><strong>Applications:<\/strong><\/td><td>For outdoor and indoor installations in damp and wet locations. They are normally used for power distribution in urban networks, industrial plants and energy distribution.<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td rowspan=\"2\">Order No.<\/td><td rowspan=\"2\">Item Code No.<\/td><td>Nominal Area<\/td><td>Nominal Insulation Thickness<\/td><td>Nominal Outer Sheath Thickness<\/td><td>Approx. Overall Diameter*&nbsp;<\/td><td>Approx. Cable Weight**&nbsp;<\/td><td>Standard Length<\/td><\/tr><tr><td>No. x mm2<\/td><td>mm<\/td><td>mm<\/td><td>mm<\/td><td>Kg\/Km<\/td><td>(mtr. \u00b1 5%)<\/td><\/tr><tr><td>L032<\/td><td>U1L1-30800R-20002K-S<\/td><td>3 x 1.5<\/td><td>0.8<\/td><td>1.8<\/td><td>11<\/td><td>175<\/td><td>1000<\/td><\/tr><tr><td>L033<\/td><td>U1L1-31000R-20002K-S<\/td><td>3 x 2.5<\/td><td>0.8<\/td><td>1.8<\/td><td>12<\/td><td>225<\/td><td>1000<\/td><\/tr><tr><td>L034<\/td><td>U1L1-31200R-20002K-S<\/td><td>3 x 4.0<\/td><td>1.0<\/td><td>1.8<\/td><td>14<\/td><td>315<\/td><td>1000<\/td><\/tr><tr><td>L035<\/td><td>U1L1-31300R-20002K-S<\/td><td>3 x 6.0<\/td><td>1.0<\/td><td>1.8<\/td><td>15<\/td><td>400<\/td><td>1000<\/td><\/tr><tr><td>L036<\/td><td>U1L1-31400R-20R02K-S<\/td><td>3 x 10<\/td><td>1.0<\/td><td>1.8<\/td><td>19<\/td><td>675<\/td><td>1000<\/td><\/tr><tr><td>L037<\/td><td>U1L1-31500R-20R02K-S<\/td><td>3 x 16<\/td><td>1.0<\/td><td>1.8<\/td><td>20<\/td><td>925<\/td><td>1000<\/td><\/tr><tr><td>L038<\/td><td>U1L1-31600S-20002K-S<\/td><td>3 x 25<\/td><td>1.2<\/td><td>1.8<\/td><td>20<\/td><td>975<\/td><td>1000<\/td><\/tr><tr><td>L039<\/td><td>U1L1-31700S-20002K-S<\/td><td>3 x 35<\/td><td>1.2<\/td><td>1.8<\/td><td>22<\/td><td>1275<\/td><td>1000<\/td><\/tr><tr><td>L040<\/td><td>U1L1-31800S-20002K-S<\/td><td>3 x 50<\/td><td>1.4<\/td><td>1.8<\/td><td>25<\/td><td>1700<\/td><td>1000<\/td><\/tr><tr><td>L041<\/td><td>U1L1-31900S-20002K-S<\/td><td>3 x 70<\/td><td>1.4<\/td><td>1.9<\/td><td>28<\/td><td>2325<\/td><td>1000<\/td><\/tr><tr><td>L042<\/td><td>U1L1-32000S-20002K-S<\/td><td>3 x 95<\/td><td>1.6<\/td><td>2.1<\/td><td>32<\/td><td>3200<\/td><td>500<\/td><\/tr><tr><td>L043<\/td><td>U1L1-32100S-20002K-S<\/td><td>3 x 120<\/td><td>1.6<\/td><td>2.2<\/td><td>34<\/td><td>3900<\/td><td>500<\/td><\/tr><tr><td>L044<\/td><td>U1L1-32200S-20002K-S<\/td><td>3 x 150<\/td><td>1.8<\/td><td>2.3<\/td><td>38<\/td><td>4875<\/td><td>500<\/td><\/tr><tr><td>L045<\/td><td>U1L1-32300S-20002K-S<\/td><td>3 x 185<\/td><td>2.0<\/td><td>2.5<\/td><td>42<\/td><td>6025<\/td><td>500<\/td><\/tr><tr><td>L046<\/td><td>U1L1-32400S-20002K-S<\/td><td>3 x 240<\/td><td>2.2<\/td><td>2.7<\/td><td>47<\/td><td>7800<\/td><td>250<\/td><\/tr><tr><td>L047<\/td><td>U1L1-32500S-20002K-S<\/td><td>3 x 300<\/td><td>2.4<\/td><td>2.9<\/td><td>52<\/td><td>9700<\/td><td>250<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>PVC Insulated, PVC Sheathed Unarmoured Cables CU \/ PVC \/ PVC Four Core With Reduced Neutral<\/strong><\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td><strong>Standard<\/strong>:<\/td><td>IEC 60502-1<\/td><td><strong>Conductor<\/strong>:<\/td><td>Class 2 stranded copper as per IEC 60228, BS EN 60228.<\/td><\/tr><tr><td><strong>Rated Voltage:<\/strong><\/td><td>0.6\/1 KV<\/td><td><strong>Insulation:<\/strong><\/td><td>PVC insulation type A as per IEC 60502-1 or type TI1 as per BS EN 50363<br>temperature rating 70 oC.<br>(PVC 90 oC is available on request).<\/td><\/tr><tr><td><strong>Shape of Conductor:<\/strong><\/td><td>16 mm2 and below, conductor shall be circular stranded non-compacted.<br>25 mm2 and above, conductor shall be sectoral stranded compacted.<\/td><td><strong>Outer Sheath:<\/strong><\/td><td>PVC outer sheath type ST1 as per IEC 60502-1 or type TM1 as per BS EN 50363.<\/td><\/tr><tr><td><\/td><td><\/td><td><strong>Applications:<\/strong><\/td><td>For outdoor and indoor installations in damp and wet locations. They are normally used for power distribution in urban networks, industrial plants and energy distribution.<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td rowspan=\"2\">Order No.<\/td><td rowspan=\"2\">Item Code No.<\/td><td>Nominal Area<\/td><td colspan=\"2\">Nominal Insulation Thickness&nbsp;(mm)<\/td><td>Nominal Outer Sheath Thickness<\/td><td>Approx. Overall Diameter*&nbsp;<\/td><td>Approx. Cable Weight**&nbsp;<\/td><td>Standard Length<\/td><\/tr><tr><td>No. x mm2<\/td><td>Ph.\u2022<\/td><td>Ne.\u2022<\/td><td>mm<\/td><td>mm<\/td><td>Kg\/Km<\/td><td>(mtr. \u00b1 5%)<\/td><\/tr><tr><td>L048<\/td><td>U1L1-41413R-20R02K-S<\/td><td>3 x 10 + 6<\/td><td>1.0<\/td><td>1.0<\/td><td>1.8<\/td><td>20<\/td><td>775<\/td><td>1000<\/td><\/tr><tr><td>L049<\/td><td>U1L1-41514R-20R02K-S<\/td><td>3 x 16 + 10<\/td><td>1.0<\/td><td>1.0<\/td><td>1.8<\/td><td>22<\/td><td>1050<\/td><td>1000<\/td><\/tr><tr><td>L050<\/td><td>U1L1-41615S-20002K-S<\/td><td>3 x 25 + 16<\/td><td>1.2<\/td><td>1.0<\/td><td>1.8<\/td><td>24<\/td><td>1275<\/td><td>1000<\/td><\/tr><tr><td>L051<\/td><td>U1L1-41715S-20002K-S<\/td><td>3 x 35 + 16<\/td><td>1.2<\/td><td>1.0<\/td><td>1.8<\/td><td>25<\/td><td>1475<\/td><td>1000<\/td><\/tr><tr><td>L052<\/td><td>U1L1-41816S-20002K-S<\/td><td>3 x 50 + 25<\/td><td>1.4<\/td><td>1.2<\/td><td>1.9<\/td><td>29<\/td><td>2000<\/td><td>1000<\/td><\/tr><tr><td>L053<\/td><td>U1L1-41917S-20002K-S<\/td><td>3 x 70 + 35<\/td><td>1.4<\/td><td>1.2<\/td><td>2.0<\/td><td>32<\/td><td>2725<\/td><td>500<\/td><\/tr><tr><td>L054<\/td><td>U1L1-42018S-20002K-S<\/td><td>3 x 95 + 50<\/td><td>1.6<\/td><td>1.4<\/td><td>2.1<\/td><td>37<\/td><td>3750<\/td><td>500<\/td><\/tr><tr><td>L055<\/td><td>U1L1-42119S-20002K-S<\/td><td>3 x 120 + 70<\/td><td>1.6<\/td><td>1.4<\/td><td>2.2<\/td><td>40<\/td><td>4650<\/td><td>500<\/td><\/tr><tr><td>L056<\/td><td>U1L1-42219S-20002K-S<\/td><td>3 x 150 + 70<\/td><td>1.8<\/td><td>1.4<\/td><td>2.4<\/td><td>44<\/td><td>5650<\/td><td>500<\/td><\/tr><tr><td>L057<\/td><td>U1L1-42320S-20002K-S<\/td><td>3 x 185 + 95<\/td><td>2.0<\/td><td>1.6<\/td><td>2.5<\/td><td>49<\/td><td>7075<\/td><td>250<\/td><\/tr><tr><td>L058<\/td><td>U1L1-42421S-20002K-S<\/td><td>3 x 240 + 120<\/td><td>2.2<\/td><td>1.6<\/td><td>2.7<\/td><td>55<\/td><td>9100<\/td><td>250<\/td><\/tr><tr><td>L059<\/td><td>U1L1-42522S-20002K-S<\/td><td>3 x 300 + 150<\/td><td>2.4<\/td><td>1.8<\/td><td>2.9<\/td><td>61<\/td><td>11300<\/td><td>250<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>PVC Insulated, PVC Sheathed Unarmoured Cables CU \/ PVC \/ PVC Four Core<\/strong><\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td><strong>Standard<\/strong>:<\/td><td>IEC 60502-1<\/td><td><strong>Conductor<\/strong>:<\/td><td>Class 2 stranded copper as per IEC 60228, BS EN 60228.<\/td><\/tr><tr><td><strong>Rated Voltage:<\/strong><\/td><td>0.6\/1 KV<\/td><td><strong>Insulation:<\/strong><\/td><td>PVC insulation type A as per IEC 60502-1 or type TI1 as per BS EN 50363<br>temperature rating 70 oC.<br>(PVC 90 oC is available on request).<\/td><\/tr><tr><td><strong>Shape of Conductor:<\/strong><\/td><td>16 mm2 and below, conductor shall be circular stranded non-compacted.<br>25 mm2 and above, conductor shall be sectoral stranded compacted.<\/td><td><strong>Outer Sheath:<\/strong><\/td><td>PVC outer sheath type ST1 as per IEC 60502-1 or type TM1 as per BS EN 50363.<\/td><\/tr><tr><td><\/td><td><\/td><td><strong>Applications:<\/strong><\/td><td>For outdoor and indoor installations in damp and wet locations. They are normally used for power distribution in urban networks, industrial plants and energy distribution.<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td rowspan=\"2\">Order No.<\/td><td rowspan=\"2\">Item Code No.<\/td><td>Nominal Area<\/td><td>Nominal Insulation Thickness<\/td><td>Nominal Outer Sheath Thickness<\/td><td>Approx. Overall Diameter*&nbsp;<\/td><td>Approx. Cable Weight**&nbsp;<\/td><td>Standard Length<\/td><\/tr><tr><td>No. x mm2<\/td><td>mm<\/td><td>mm<\/td><td>mm<\/td><td>Kg\/Km<\/td><td>(mtr. \u00b1 5%)<\/td><\/tr><tr><td>L060<\/td><td>U1L1-40800R-20002K-S<\/td><td>4 x 1.5<\/td><td>0.8<\/td><td>1.8<\/td><td>12<\/td><td>210<\/td><td>1000<\/td><\/tr><tr><td>L061<\/td><td>U1L1-41000R-20002K-S<\/td><td>4 x 2.5<\/td><td>0.8<\/td><td>1.8<\/td><td>13<\/td><td>275<\/td><td>1000<\/td><\/tr><tr><td>L062<\/td><td>U1L1-41200R-20002K-S<\/td><td>4 x 4.0<\/td><td>1.0<\/td><td>1.8<\/td><td>15<\/td><td>400<\/td><td>1000<\/td><\/tr><tr><td>L063<\/td><td>U1L1-41300R-20002K-S<\/td><td>4 x 6.0<\/td><td>1.0<\/td><td>1.8<\/td><td>16<\/td><td>500<\/td><td>1000<\/td><\/tr><tr><td>L064<\/td><td>U1L1-41400R-20R02K-S<\/td><td>4 x 10<\/td><td>1.0<\/td><td>1.8<\/td><td>21<\/td><td>825<\/td><td>1000<\/td><\/tr><tr><td>L065<\/td><td>U1L1-41500R-20R02K-S<\/td><td>4 x 16<\/td><td>1.0<\/td><td>1.8<\/td><td>23<\/td><td>1150<\/td><td>1000<\/td><\/tr><tr><td>L066<\/td><td>U1L1-41600S-20002K-S<\/td><td>4 x 25<\/td><td>1.2<\/td><td>1.8<\/td><td>23<\/td><td>1275<\/td><td>1000<\/td><\/tr><tr><td>L067<\/td><td>U1L1-41700S-20002K-S<\/td><td>4 x 35<\/td><td>1.2<\/td><td>1.8<\/td><td>26<\/td><td>1675<\/td><td>1000<\/td><\/tr><tr><td>L068<\/td><td>U1L1-41800S-20002K-S<\/td><td>4 x 50<\/td><td>1.4<\/td><td>1.9<\/td><td>30<\/td><td>2250<\/td><td>1000<\/td><\/tr><tr><td>L069<\/td><td>U1L1-41900S-20002K-S<\/td><td>4 x 70<\/td><td>1.4<\/td><td>2.1<\/td><td>33<\/td><td>3100<\/td><td>500<\/td><\/tr><tr><td>L070<\/td><td>U1L1-42000S-20002K-S<\/td><td>4 x 95<\/td><td>1.6<\/td><td>2.2<\/td><td>38<\/td><td>4250<\/td><td>500<\/td><\/tr><tr><td>L071<\/td><td>U1L1-42100S-20002K-S<\/td><td>4 x 120<\/td><td>1.6<\/td><td>2.3<\/td><td>41<\/td><td>5200<\/td><td>500<\/td><\/tr><tr><td>L072<\/td><td>U1L1-42200S-20002K-S<\/td><td>4 x 150<\/td><td>1.8<\/td><td>2.5<\/td><td>46<\/td><td>6500<\/td><td>500<\/td><\/tr><tr><td>L073<\/td><td>U1L1-42300S-20002K-S<\/td><td>4 x 185<\/td><td>2.0<\/td><td>2.7<\/td><td>51<\/td><td>8050<\/td><td>250<\/td><\/tr><tr><td>L074<\/td><td>U1L1-42400S-20002K-S<\/td><td>4 x 240<\/td><td>2.2<\/td><td>2.9<\/td><td>57<\/td><td>10400<\/td><td>250<\/td><\/tr><tr><td>L075<\/td><td>U1L1-42500S-20002K-S<\/td><td>4 x 300<\/td><td>2.4<\/td><td>3.1<\/td><td>63<\/td><td>12950<\/td><td>250<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>PVC Insulated, PVC Sheathed Unarmoured Cables CU \/ PVC \/ PVC Five Core<\/strong><\/h3>\n\n\n\n<figure class=\"wp-block-image\"><img decoding=\"async\" src=\"https:\/\/web.archive.org\/web\/20240913110739im_\/https:\/\/wadiseercables.com\/wp-content\/uploads\/2024\/07\/image-removebg-preview-2024-07-17T204317.749.png\" alt=\"\" title=\"image-removebg-preview - 2024-07-17T204317.749\"\/><\/figure>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td><strong>Standard<\/strong>:<\/td><td>IEC 60502-1<\/td><td><strong>Conductor<\/strong>:<\/td><td>Class 2 stranded copper as per IEC 60228, BS EN 60228.<\/td><\/tr><tr><td><strong>Rated Voltage:<\/strong><\/td><td>0.6\/1 KV<\/td><td><strong>Insulation:<\/strong><\/td><td>PVC insulation type A as per IEC 60502-1 or type TI1 as per BS EN 50363<br>temperature rating 70 oC.<br>(PVC 90 oC is available on request).<\/td><\/tr><tr><td><strong>Shape of Conductor:<\/strong><\/td><td>16 mm2 and below, conductor shall be circular stranded non-compacted.<br>25 mm2 and above, conductor shall be sectoral stranded compacted.<\/td><td><strong>Outer Sheath:<\/strong><\/td><td>PVC outer sheath type ST1 as per IEC 60502-1 or type TM1 as per BS EN 50363.<\/td><\/tr><tr><td><\/td><td><\/td><td><strong>Applications:<\/strong><\/td><td>For outdoor and indoor installations in damp and wet locations. They are normally used for power distribution in urban networks, industrial plants and energy distribution.<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td rowspan=\"2\">Order No.<\/td><td rowspan=\"2\">Item Code No.<\/td><td>Nominal Area<\/td><td>Nominal Insulation Thickness<\/td><td>Nominal Outer Sheath Thickness<\/td><td>Approx. Overall Diameter*&nbsp;<\/td><td>Approx. Cable Weight**&nbsp;<\/td><td>Standard Length<\/td><\/tr><tr><td>No. x mm2<\/td><td>mm<\/td><td>mm<\/td><td>mm<\/td><td>Kg\/Km<\/td><td>(mtr. \u00b1 5%)<\/td><\/tr><tr><td>L076<\/td><td>U1L1-50800R-20002K-S<\/td><td>5 x 1.5<\/td><td>0.8<\/td><td>1.8<\/td><td>13<\/td><td>250<\/td><td>1000<\/td><\/tr><tr><td>L077<\/td><td>U1L1-51000R-20002K-S<\/td><td>5 x 2.5<\/td><td>0.8<\/td><td>1.8<\/td><td>14<\/td><td>325<\/td><td>1000<\/td><\/tr><tr><td>L078<\/td><td>U1L1-51200R-20002K-S<\/td><td>5 x 4.0<\/td><td>1.0<\/td><td>1.8<\/td><td>16<\/td><td>475<\/td><td>1000<\/td><\/tr><tr><td>L079<\/td><td>U1L1-51300R-20002K-S<\/td><td>5 x 6.0<\/td><td>1.0<\/td><td>1.8<\/td><td>18<\/td><td>615<\/td><td>1000<\/td><\/tr><tr><td>L080<\/td><td>U1L1-51400R-20R02K-S<\/td><td>5 x 10<\/td><td>1.0<\/td><td>1.8<\/td><td>22<\/td><td>1020<\/td><td>1000<\/td><\/tr><tr><td>L081<\/td><td>U1L1-51500R-20R02K-S<\/td><td>5 x 16<\/td><td>1.0<\/td><td>1.8<\/td><td>25<\/td><td>1400<\/td><td>1000<\/td><\/tr><tr><td>L082<\/td><td>U1L1-51600C-20202K-S<\/td><td>5 x 25<\/td><td>1.2<\/td><td>1.8<\/td><td>29<\/td><td>1900<\/td><td>500<\/td><\/tr><tr><td>L083<\/td><td>U1L1-51700C-20202K-S<\/td><td>5 x 35<\/td><td>1.2<\/td><td>1.9<\/td><td>32<\/td><td>2550<\/td><td>500<\/td><\/tr><tr><td>L084<\/td><td>U1L1-51800C-20202K-S<\/td><td>5 x 50<\/td><td>1.4<\/td><td>2.0<\/td><td>37<\/td><td>3400<\/td><td>500<\/td><\/tr><tr><td>L085<\/td><td>U1L1-51900C-20202K-S<\/td><td>5 x 70<\/td><td>1.4<\/td><td>2.2<\/td><td>42<\/td><td>4600<\/td><td>500<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">\u0643\u0627\u0628\u0644\u0627\u062a \u0646\u062d\u0627\u0633\u064a\u0629 \u0645\u0639\u0632\u0648\u0644\u0629 \u0628\u0645\u0627\u062f\u0629 PVC (\u0645\u0633\u0644\u062d)<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>PVC Insulated, PVC Sheathed Armoured Cables CU \/ PVC \/ AWA \/ PVC Single Core<\/strong><\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td><strong>tandard<\/strong>:<\/td><td>IEC 60502-1, BS 6346<\/td><td><strong>Conductor<\/strong>:<\/td><td>Class 2 stranded copper as per IEC 60228, BS EN 60228<\/td><\/tr><tr><td><strong>Rated Voltage:<\/strong><\/td><td>0.6\/1 KV<\/td><td><strong>Insulation:<\/strong><\/td><td>PVC insulation type A as per IEC 60502-1 or type TI1 as per BS EN 50363 temperature rating 70 o C. (PVC 90 o C is available on request).<\/td><\/tr><tr><td><strong>Shape of Conductor:<\/strong><\/td><td>Conductor shall be circular stranded compacted.<\/td><td><strong>Outer Sheath:<\/strong><\/td><td>PVC outer sheath type ST1 as per IEC 60502-1 or type TM1 as per BS EN 50363.<\/td><\/tr><tr><td><strong>Armour<\/strong>:<\/td><td>Aluminum wires applied helically as per IEC 60502-1 or BS 6346<\/td><td><strong>Applications:<\/strong><\/td><td>For outdoor installations in damp and wet locations. They are normally used for power distribution in urban networks, industrial plants and energy distribution where mechanical damage expected to occur.<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td rowspan=\"2\">Order No.<\/td><td rowspan=\"2\">Item Code No.<\/td><td>Nominal Area<\/td><td>Nominal Insulation Thickness<\/td><td>Nominal Aluminum Wire Diameter<\/td><td>Nominal Outer Sheath Thickness<\/td><td>Approx. Overall Diameter*&nbsp;<\/td><td>Approx. Cable Weight**&nbsp;<\/td><td>Standard Length<\/td><\/tr><tr><td>No. x mm2<\/td><td>mm<\/td><td>mm<\/td><td>mm<\/td><td>mm<\/td><td>Kg\/Km<\/td><td>(mtr. \u00b1 5%)<\/td><\/tr><tr><td>L086<\/td><td>U1L1-11800C-20222K-S<\/td><td>1 x 50<\/td><td>1.4<\/td><td>1.25<\/td><td>1.8<\/td><td>20<\/td><td>850<\/td><td>1000<\/td><\/tr><tr><td>L087<\/td><td>U1L1-11900C-20222K-S<\/td><td>1 x 70<\/td><td>1.4<\/td><td>1.25<\/td><td>1.8<\/td><td>21<\/td><td>1075<\/td><td>1000<\/td><\/tr><tr><td>L088<\/td><td>U1L1-12000C-20222K-S<\/td><td>1 x 95<\/td><td>1.6<\/td><td>1.25<\/td><td>1.8<\/td><td>23<\/td><td>1400<\/td><td>1000<\/td><\/tr><tr><td>L089<\/td><td>U1L1-12100C-20222K-S<\/td><td>1 x 120<\/td><td>1.6<\/td><td>1.60<\/td><td>1.8<\/td><td>26<\/td><td>1700<\/td><td>1000<\/td><\/tr><tr><td>L090<\/td><td>U1L1-12200C-20222K-S<\/td><td>1 x 150<\/td><td>1.8<\/td><td>1.60<\/td><td>1.8<\/td><td>27<\/td><td>2050<\/td><td>1000<\/td><\/tr><tr><td>L091<\/td><td>U1L1-12300C-20222K-S<\/td><td>1 x 185<\/td><td>2.0<\/td><td>1.60<\/td><td>1.8<\/td><td>29<\/td><td>2450<\/td><td>1000<\/td><\/tr><tr><td>L092<\/td><td>U1L1-12400C-20222K-S<\/td><td>1 x 240<\/td><td>2.2<\/td><td>1.60<\/td><td>1.9<\/td><td>32<\/td><td>3100<\/td><td>500<\/td><\/tr><tr><td>L093<\/td><td>U1L1-12500C-20222K-S<\/td><td>1 x 300<\/td><td>2.4<\/td><td>2.00<\/td><td>2.0<\/td><td>36<\/td><td>3900<\/td><td>500<\/td><\/tr><tr><td>L094<\/td><td>U1L1-12600C-20222K-S<\/td><td>1 x 400<\/td><td>2.6<\/td><td>2.00<\/td><td>2.1<\/td><td>40<\/td><td>4850<\/td><td>500<\/td><\/tr><tr><td>L095<\/td><td>U1L1-12700C-20222K-S<\/td><td>1 x 500<\/td><td>2.8<\/td><td>2.00<\/td><td>2.2<\/td><td>44<\/td><td>5975<\/td><td>500<\/td><\/tr><tr><td>L096<\/td><td>U1L1-12900C-20222K-S<\/td><td>1 x 630<\/td><td>2.8<\/td><td>2.00<\/td><td>2.4<\/td><td>47<\/td><td>7366<\/td><td>500<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>PVC Insulated, PVC Sheathed Armoured Cables CU \/ PVC \/ SWA \/ PVC Two Core<\/strong><\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td><strong>tandard<\/strong>:<\/td><td>IEC 60502-1, BS 6346<\/td><td><strong>Conductor<\/strong>:<\/td><td>Class 2 stranded copper as per IEC 60228, BS EN 60228<\/td><\/tr><tr><td><strong>Rated Voltage:<\/strong><\/td><td>0.6\/1 KV<\/td><td><strong>Insulation:<\/strong><\/td><td>PVC insulation type A as per IEC 60502-1 or type TI1 as per BS EN 50363 temperature rating 70 o C. (PVC 90 o C is available on request).<\/td><\/tr><tr><td><strong>Shape of Conductor:<\/strong><\/td><td>Conductor shall be circular stranded compacted.<\/td><td><strong>Outer Sheath:<\/strong><\/td><td>PVC outer sheath type ST1 as per IEC 60502-1 or type TM1 as per BS EN 50363.<\/td><\/tr><tr><td><strong>Armour<\/strong>:<\/td><td>Galvanized steel wires applied helically as per IEC 60502-1 or BS 6346<\/td><td><strong>Applications:<\/strong><\/td><td>For outdoor installations in damp and wet locations. They are normally used for power distribution in urban networks, industrial plants and energy distribution where mechanical damage expected to occur.<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td rowspan=\"2\">Order No.<\/td><td rowspan=\"2\">Item Code No.<\/td><td>Nominal Area<\/td><td>Nominal Insulation Thickness<\/td><td>Nominal Aluminum Wire Diameter<\/td><td>Nominal Outer Sheath Thickness<\/td><td>Approx. Overall Diameter*&nbsp;<\/td><td>Approx. Cable Weight**&nbsp;<\/td><td>Standard Length<\/td><\/tr><tr><td>No. x mm2<\/td><td>mm<\/td><td>mm<\/td><td>mm<\/td><td>mm<\/td><td>Kg\/Km<\/td><td>(mtr. \u00b1 5%)<\/td><\/tr><tr><td>L097<\/td><td>U1L1-20800R-20212K-S<\/td><td>2 x 1.5<\/td><td>0.8<\/td><td>0.9<\/td><td>1.8<\/td><td>14<\/td><td>375<\/td><td>1000<\/td><\/tr><tr><td>L098<\/td><td>U1L1-21000R-20212K-S<\/td><td>2 x 2.5<\/td><td>0.8<\/td><td>0.9<\/td><td>1.8<\/td><td>15<\/td><td>435<\/td><td>1000<\/td><\/tr><tr><td>L099<\/td><td>U1L1-21200R-20212K-S<\/td><td>2 x 4.0<\/td><td>1.0<\/td><td>0.9<\/td><td>1.8<\/td><td>17<\/td><td>550<\/td><td>1000<\/td><\/tr><tr><td>L100<\/td><td>U1L1-21300R-20212K-S<\/td><td>2 x 6.0<\/td><td>1.0<\/td><td>1.25<\/td><td>1.8<\/td><td>19<\/td><td>730<\/td><td>1000<\/td><\/tr><tr><td>L101<\/td><td>U1L1-21400R-20212K-S<\/td><td>2 x 10<\/td><td>1.0<\/td><td>1.25<\/td><td>1.8<\/td><td>21<\/td><td>925<\/td><td>1000<\/td><\/tr><tr><td>L102<\/td><td>U1L1-21500R-20212K-S<\/td><td>2 x 16<\/td><td>1.0<\/td><td>1.25<\/td><td>1.8<\/td><td>23<\/td><td>1150<\/td><td>1000<\/td><\/tr><tr><td>L103<\/td><td>U1L1-21600C-20212K-S<\/td><td>2 x 25<\/td><td>1.2<\/td><td>1.6<\/td><td>1.8<\/td><td>26<\/td><td>1625<\/td><td>1000<\/td><\/tr><tr><td>L104<\/td><td>U1L1-21700C-20212K-S<\/td><td>2 x 35<\/td><td>1.2<\/td><td>1.6<\/td><td>1.8<\/td><td>28<\/td><td>1975<\/td><td>1000<\/td><\/tr><tr><td>L105<\/td><td>U1L1-21800C-20212K-S<\/td><td>2 x 50<\/td><td>1.4<\/td><td>1.6<\/td><td>1.9<\/td><td>32<\/td><td>2500<\/td><td>500<\/td><\/tr><tr><td>L106<\/td><td>U1L1-21900C-20212K-S<\/td><td>2 x 70<\/td><td>1.4<\/td><td>2.0<\/td><td>2.0<\/td><td>36<\/td><td>3400<\/td><td>500<\/td><\/tr><tr><td>L107<\/td><td>U1L1-22000C-20212K-S<\/td><td>2 x 95<\/td><td>1.6<\/td><td>2.0<\/td><td>2.2<\/td><td>41<\/td><td>4325<\/td><td>500<\/td><\/tr><tr><td>L108<\/td><td>U1L1-22100C-20212K-S<\/td><td>2 x 120<\/td><td>1.6<\/td><td>2.0<\/td><td>2.3<\/td><td>44<\/td><td>5050<\/td><td>500<\/td><\/tr><tr><td>L109<\/td><td>U1L1-22200C-20212K-S<\/td><td>2 x 150<\/td><td>1.8<\/td><td>2.0<\/td><td>2.4<\/td><td>49<\/td><td>6550<\/td><td>500<\/td><\/tr><tr><td>L110<\/td><td>U1L1-22300C-20212K-S<\/td><td>2 x 185<\/td><td>2.0<\/td><td>2.5<\/td><td>2.6<\/td><td>54<\/td><td>7750<\/td><td>250<\/td><\/tr><tr><td>L111<\/td><td>U1L1-22400C-20212K-S<\/td><td>2 x 240<\/td><td>2.2<\/td><td>2.5<\/td><td>2.8<\/td><td>60<\/td><td>9625<\/td><td>250<\/td><\/tr><tr><td>L112<\/td><td>U1L1-22500C-20212K-S<\/td><td>2 x 300<\/td><td>2.4<\/td><td>2.5<\/td><td>2.9<\/td><td>65<\/td><td>11550<\/td><td>250<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>PVC Insulated, PVC Sheathed Armoured Cables CU \/ PVC \/ SWA \/ PVC Three Core<\/strong><\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td><strong>tandard<\/strong>:<\/td><td>IEC 60502-1, BS 6346<\/td><td><strong>Conductor<\/strong>:<\/td><td>Class 2 stranded copper as per IEC 60228, BS EN 60228<\/td><\/tr><tr><td><strong>Rated Voltage:<\/strong><\/td><td>0.6\/1 KV<\/td><td><strong>Insulation:<\/strong><\/td><td>PVC insulation type A as per IEC 60502-1 or type TI1 as per BS EN 50363 temperature rating 70 o C. (PVC 90 o C is available on request).<\/td><\/tr><tr><td><strong>Shape of Conductor:<\/strong><\/td><td>Conductor shall be circular stranded compacted.<\/td><td><strong>Outer Sheath:<\/strong><\/td><td>PVC outer sheath type ST1 as per IEC 60502-1 or type TM1 as per BS EN 50363.<\/td><\/tr><tr><td><strong>Armour<\/strong>:<\/td><td>Galvanized steel wires applied helically as per IEC 60502-1 or BS 6346<\/td><td><strong>Applications:<\/strong><\/td><td>For outdoor installations in damp and wet locations. They are normally used for power distribution in urban networks, industrial plants and energy distribution where mechanical damage expected to occur.<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td rowspan=\"2\">Order No.<\/td><td rowspan=\"2\">Item Code No.<\/td><td>Nominal Area<\/td><td>Nominal Insulation Thickness<\/td><td>Nominal Steel Wire Diameter<\/td><td>Nominal Outer Sheath Thickness<\/td><td>Approx. Overall Diameter*&nbsp;<\/td><td>Approx. Cable Weight**&nbsp;<\/td><td>Standard Length<\/td><\/tr><tr><td>No. x mm2<\/td><td>mm<\/td><td>mm<\/td><td>mm<\/td><td>mm<\/td><td>Kg\/Km<\/td><td>(mtr. \u00b1 5%)<\/td><\/tr><tr><td>L113<\/td><td>U1L1-30800R-20212K-S<\/td><td>3 x 1.5<\/td><td>0.8<\/td><td>0.9<\/td><td>1.8<\/td><td>15<\/td><td>425<\/td><td>1000<\/td><\/tr><tr><td>L114<\/td><td>U1L1-31000R-20212K-S<\/td><td>3 x 2.5<\/td><td>0.8<\/td><td>0.9<\/td><td>1.8<\/td><td>16<\/td><td>500<\/td><td>1000<\/td><\/tr><tr><td>L115<\/td><td>U1L1-31200R-20212K-S<\/td><td>3 x 4.0<\/td><td>1.0<\/td><td>1.25<\/td><td>1.8<\/td><td>18<\/td><td>725<\/td><td>1000<\/td><\/tr><tr><td>L116<\/td><td>U1L1-31300R-20212K-S<\/td><td>3 x 6.0<\/td><td>1.0<\/td><td>1.25<\/td><td>1.8<\/td><td>20<\/td><td>850<\/td><td>1000<\/td><\/tr><tr><td>L117<\/td><td>U1L1-31400R-20212K-S<\/td><td>3 x 10<\/td><td>1.0<\/td><td>1.25<\/td><td>1.8<\/td><td>22<\/td><td>1075<\/td><td>1000<\/td><\/tr><tr><td>L118<\/td><td>U1L1-31500R-20212K-S<\/td><td>3 x 16<\/td><td>1.0<\/td><td>1.25<\/td><td>1.8<\/td><td>24<\/td><td>1350<\/td><td>1000<\/td><\/tr><tr><td>L119<\/td><td>U1L1-31600S-20212K-S<\/td><td>3 x 25<\/td><td>1.2<\/td><td>1.6<\/td><td>1.8<\/td><td>24<\/td><td>1700<\/td><td>1000<\/td><\/tr><tr><td>L120<\/td><td>U1L1-31700S-20212K-S<\/td><td>3 x 35<\/td><td>1.2<\/td><td>1.6<\/td><td>1.8<\/td><td>26<\/td><td>2075<\/td><td>1000<\/td><\/tr><tr><td>L121<\/td><td>U1L1-31800S-20212K-S<\/td><td>3 x 50<\/td><td>1.4<\/td><td>1.6<\/td><td>2.0<\/td><td>30<\/td><td>2650<\/td><td>1000<\/td><\/tr><tr><td>L122<\/td><td>U1L1-31900S-20212K-S<\/td><td>3 x 70<\/td><td>1.4<\/td><td>2.0<\/td><td>2.1<\/td><td>34<\/td><td>3550<\/td><td>500<\/td><\/tr><tr><td>L123<\/td><td>U1L1-32000S-20212K-S<\/td><td>3 x 95<\/td><td>1.6<\/td><td>2.0<\/td><td>2.2<\/td><td>38<\/td><td>4650<\/td><td>500<\/td><\/tr><tr><td>L124<\/td><td>U1L1-32100S-20212K-S<\/td><td>3 x 120<\/td><td>1.6<\/td><td>2.0<\/td><td>2.3<\/td><td>40<\/td><td>5450<\/td><td>500<\/td><\/tr><tr><td>L125<\/td><td>U1L1-32200S-20212K-S<\/td><td>3 x 150<\/td><td>1.8<\/td><td>2.5<\/td><td>2.5<\/td><td>46<\/td><td>7025<\/td><td>500<\/td><\/tr><tr><td>L126<\/td><td>U1L1-32300S-20212K-S<\/td><td>3 x 185<\/td><td>2.0<\/td><td>2.5<\/td><td>2.7<\/td><td>50<\/td><td>8400<\/td><td>500<\/td><\/tr><tr><td>L127<\/td><td>U1L1-32400S-20212K-S<\/td><td>3 x 240<\/td><td>2.2<\/td><td>2.5<\/td><td>2.9<\/td><td>55<\/td><td>10450<\/td><td>250<\/td><\/tr><tr><td>L128<\/td><td>U1L1-32500S-20212K-S<\/td><td>3 x 300<\/td><td>2.4<\/td><td>2.5<\/td><td>3.1<\/td><td>60<\/td><td>12700<\/td><td>250<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td rowspan=\"2\">Order No.<\/td><td rowspan=\"2\">Item Code No.<\/td><td>Nominal Area<\/td><td colspan=\"2\">Nominal Insulation Thickness(mm)<\/td><td>Nominal Steel Wire Diameter<\/td><td>Nominal Outer Sheath Thickness<\/td><td>Approx. Overall Diameter*&nbsp;<\/td><td>Approx. Cable Weight**&nbsp;<\/td><td>Standard Length<\/td><\/tr><tr><td>No. x mm2<\/td><td>Ph.\u2022<\/td><td>Ne.\u2022<\/td><td>mm<\/td><td>mm<\/td><td>mm<\/td><td>Kg\/Km<\/td><td>(mtr. \u00b1 5%)<\/td><\/tr><tr><td>L129<\/td><td>U1L1-41413R-20212K-S<\/td><td>3 x 10 + 6<\/td><td>1.0<\/td><td>1.0<\/td><td>1.25<\/td><td>1.8<\/td><td>23<\/td><td>1150<\/td><td>1000<\/td><\/tr><tr><td>L130<\/td><td>U1L1-41514R-20212K-S<\/td><td>3 x 16 + 10<\/td><td>1.0<\/td><td>1.0<\/td><td>1.60<\/td><td>1.8<\/td><td>26<\/td><td>1625<\/td><td>1000<\/td><\/tr><tr><td>L131<\/td><td>U1L1-41615S-20212K-S<\/td><td>3 x 25 + 16<\/td><td>1.2<\/td><td>1.0<\/td><td>1.60<\/td><td>1.8<\/td><td>27<\/td><td>1950<\/td><td>1000<\/td><\/tr><tr><td>L132<\/td><td>U1L1-41715S-20212K-S<\/td><td>3 x 35 + 16<\/td><td>1.2<\/td><td>1.0<\/td><td>1.60<\/td><td>1.8<\/td><td>30<\/td><td>2350<\/td><td>1000<\/td><\/tr><tr><td>L133<\/td><td>U1L1-41816S-20212K-S<\/td><td>3 x 50 + 25<\/td><td>1.4<\/td><td>1.2<\/td><td>2.00<\/td><td>2.0<\/td><td>35<\/td><td>3275<\/td><td>500<\/td><\/tr><tr><td>L134<\/td><td>U1L1-41917S-20212K-S<\/td><td>3 x 70 + 35<\/td><td>1.4<\/td><td>1.2<\/td><td>2.00<\/td><td>2.1<\/td><td>38<\/td><td>4200<\/td><td>500<\/td><\/tr><tr><td>L135<\/td><td>U1L1-42018S-20212K-S<\/td><td>3 x 95 + 50<\/td><td>1.6<\/td><td>1.4<\/td><td>2.00<\/td><td>2.2<\/td><td>43<\/td><td>5400<\/td><td>500<\/td><\/tr><tr><td>L136<\/td><td>U1L1-42119S-20212K-S<\/td><td>3 x 120 + 70<\/td><td>1.6<\/td><td>1.4<\/td><td>2.50<\/td><td>2.4<\/td><td>47<\/td><td>6900<\/td><td>500<\/td><\/tr><tr><td>L137<\/td><td>U1L1-42219S-20212K-S<\/td><td>3 x 150 + 70<\/td><td>1.8<\/td><td>1.4<\/td><td>2.50<\/td><td>2.5<\/td><td>52<\/td><td>8150<\/td><td>250<\/td><\/tr><tr><td>L138<\/td><td>U1L1-42320S-20212K-S<\/td><td>3 x 185 + 95<\/td><td>2.0<\/td><td>1.6<\/td><td>2.50<\/td><td>2.7<\/td><td>57<\/td><td>9850<\/td><td>250<\/td><\/tr><tr><td>L139<\/td><td>U1L1-42421S-20212K-S<\/td><td>3 x 240 + 120<\/td><td>2.2<\/td><td>1.6<\/td><td>2.50<\/td><td>2.9<\/td><td>63<\/td><td>12300<\/td><td>250<\/td><\/tr><tr><td>L140<\/td><td>U1L1-42522S-20212K-S<\/td><td>3 x 300 + 150<\/td><td>2.4<\/td><td>1.8<\/td><td>2.50<\/td><td>3.1<\/td><td>69<\/td><td>14800<\/td><td>250<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td rowspan=\"2\">Order No.<\/td><td rowspan=\"2\">Item Code No.<\/td><td>Nominal Area<\/td><td>Nominal Insulation Thickness<\/td><td>Nominal Steel Wire Diameter<\/td><td>Nominal Outer Sheath Thickness<\/td><td>Approx. Overall Diameter*&nbsp;<\/td><td>Approx. Cable Weight**&nbsp;<\/td><td>Standard Length<\/td><\/tr><tr><td>No. x mm2<\/td><td>mm<\/td><td>mm<\/td><td>mm<\/td><td>mm<\/td><td>Kg\/Km<\/td><td>(mtr. \u00b1 5%)<\/td><\/tr><tr><td>L141<\/td><td>U1L1-40800R-20212K-S<\/td><td>4 x 1.5<\/td><td>0.8<\/td><td>0.90<\/td><td>1.8<\/td><td>16<\/td><td>475<\/td><td>1000<\/td><\/tr><tr><td>L142<\/td><td>U1L1-41000R-20212K-S<\/td><td>4 x 2.5<\/td><td>0.8<\/td><td>0.90<\/td><td>1.8<\/td><td>17<\/td><td>550<\/td><td>1000<\/td><\/tr><tr><td>L143<\/td><td>U1L1-41200R-20212K-S<\/td><td>4 x 4.0<\/td><td>1.0<\/td><td>1.25<\/td><td>1.8<\/td><td>20<\/td><td>825<\/td><td>1000<\/td><\/tr><tr><td>L144<\/td><td>U1L1-41300R-20212K-S<\/td><td>4 x 6.0<\/td><td>1.0<\/td><td>1.25<\/td><td>1.8<\/td><td>21<\/td><td>975<\/td><td>1000<\/td><\/tr><tr><td>L145<\/td><td>U1L1-41400R-20212K-S<\/td><td>4 x 10<\/td><td>1.0<\/td><td>1.25<\/td><td>1.8<\/td><td>23<\/td><td>1225<\/td><td>1000<\/td><\/tr><tr><td>L146<\/td><td>U1L1-41500R-20212K-S<\/td><td>4 x 16<\/td><td>1.0<\/td><td>1.60<\/td><td>1.8<\/td><td>26<\/td><td>1725<\/td><td>1000<\/td><\/tr><tr><td>L147<\/td><td>U1L1-41600S-20212K-S<\/td><td>4 x 25<\/td><td>1.2<\/td><td>1.60<\/td><td>1.8<\/td><td>28<\/td><td>2075<\/td><td>1000<\/td><\/tr><tr><td>L148<\/td><td>U1L1-41700S-20212K-S<\/td><td>4 x 35<\/td><td>1.2<\/td><td>1.60<\/td><td>1.9<\/td><td>30<\/td><td>2575<\/td><td>1000<\/td><\/tr><tr><td>L149<\/td><td>U1L1-41800S-20212K-S<\/td><td>4 x 50<\/td><td>1.4<\/td><td>2.00&nbsp;<\/td><td>2.1<\/td><td>36<\/td><td>3575<\/td><td>500<\/td><\/tr><tr><td>L150<\/td><td>U1L1-41900S-20212K-S<\/td><td>4 x 70<\/td><td>1.4<\/td><td>2.00&nbsp;<\/td><td>2.2<\/td><td>39<\/td><td>4600<\/td><td>500<\/td><\/tr><tr><td>L151<\/td><td>U1L1-42000S-20212K-S<\/td><td>4 x 95<\/td><td>1.6<\/td><td>2.50<\/td><td>2.4<\/td><td>45<\/td><td>6375<\/td><td>500<\/td><\/tr><tr><td>L152<\/td><td>U1L1-42100S-20212K-S<\/td><td>4 x 120<\/td><td>1.6<\/td><td>2.50<\/td><td>2.5<\/td><td>49<\/td><td>7525<\/td><td>500<\/td><\/tr><tr><td>L153<\/td><td>U1L1-42200S-20212K-S<\/td><td>4 x 150<\/td><td>1.8<\/td><td>2.50<\/td><td>2.7<\/td><td>54<\/td><td>9050<\/td><td>250<\/td><\/tr><tr><td>L154<\/td><td>U1L1-42300S-20212K-S<\/td><td>4 x 185<\/td><td>2.0<\/td><td>2.50<\/td><td>2.9<\/td><td>59<\/td><td>10900<\/td><td>250<\/td><\/tr><tr><td>L155<\/td><td>U1L1-42400S-20212K-S<\/td><td>4 x 240<\/td><td>2.2<\/td><td>2.50<\/td><td>3.1<\/td><td>65<\/td><td>13600<\/td><td>250<\/td><\/tr><tr><td>L156<\/td><td>U1L1-42500S-20212K-S<\/td><td>4 x 300<\/td><td>2.4<\/td><td>2.50<\/td><td>3.3<\/td><td>71<\/td><td>16525<\/td><td>250<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td rowspan=\"2\">Order No.<\/td><td rowspan=\"2\">Item Code No.<\/td><td>Nominal Area<\/td><td>Nominal Insulation Thickness<\/td><td>Nominal Steel Tape Thickness<\/td><td>Nominal Outer Sheath Thickness<\/td><td>Approx. Overall Diameter*&nbsp;<\/td><td>Approx. Cable Weight**&nbsp;<\/td><td>Standard Length<\/td><\/tr><tr><td>No. x mm2<\/td><td>mm<\/td><td>mm<\/td><td>mm<\/td><td>mm<\/td><td>Kg\/Km<\/td><td>(mtr. \u00b1 5%)<\/td><\/tr><tr><td>L157<\/td><td>U1L1-50800R-20212K-S<\/td><td>5 x 1.5<\/td><td>0.8<\/td><td>0.90<\/td><td>1.8<\/td><td>16<\/td><td>525<\/td><td>1000<\/td><\/tr><tr><td>L158<\/td><td>U1L1-51000R-20212K-S<\/td><td>5 x 2.5<\/td><td>0.8<\/td><td>0.90<\/td><td>1.8<\/td><td>18<\/td><td>630<\/td><td>1000<\/td><\/tr><tr><td>L159<\/td><td>U1L1-51200R-20212K-S<\/td><td>5 x 4.0<\/td><td>1.0<\/td><td>1.25<\/td><td>1.8<\/td><td>21<\/td><td>925<\/td><td>1000<\/td><\/tr><tr><td>L160<\/td><td>U1L1-51300R-20212K-S<\/td><td>5 x 6.0<\/td><td>1.0<\/td><td>1.25<\/td><td>1.8<\/td><td>22<\/td><td>1125<\/td><td>1000<\/td><\/tr><tr><td>L161<\/td><td>U1L1-51400R-20212K-S<\/td><td>5 x 10<\/td><td>1.0<\/td><td>1.60<\/td><td>1.8<\/td><td>26<\/td><td>1575<\/td><td>1000<\/td><\/tr><tr><td>L162<\/td><td>U1L1-51500R-20212K-S<\/td><td>5 x 16<\/td><td>1.0<\/td><td>1.60<\/td><td>1.8<\/td><td>28<\/td><td>2050<\/td><td>1000<\/td><\/tr><tr><td>L163<\/td><td>U1L1-51600C-20212K-S<\/td><td>5 x 25<\/td><td>1.2<\/td><td>1.60<\/td><td>1.9<\/td><td>32<\/td><td>2725<\/td><td>500<\/td><\/tr><tr><td>L164<\/td><td>U1L1-51700C-20212K-S<\/td><td>5 x 35<\/td><td>1.2<\/td><td>2.00<\/td><td>2.0<\/td><td>36<\/td><td>3700<\/td><td>500<\/td><\/tr><tr><td>L165<\/td><td>U1L1-51800C-20212K-S<\/td><td>5 x 50<\/td><td>1.4<\/td><td>2.00<\/td><td>2.2<\/td><td>42<\/td><td>4800<\/td><td>500<\/td><\/tr><tr><td>L166<\/td><td>U1L1-51900C-20212K-S<\/td><td>5 x 70<\/td><td>1.4<\/td><td>2.00<\/td><td>2.3<\/td><td>46<\/td><td>6100<\/td><td>500<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">\u0643\u0627\u0628\u0644\u0627\u062a \u0646\u062d\u0627\u0633\u064a\u0629 \u0645\u0639\u0632\u0648\u0644\u0629 \u0628\u0640 XLPE (\u063a\u064a\u0631 \u0645\u0633\u0644\u062d)<\/h2>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td>L221<\/td><td>U1L1-11400R-10002K-S<\/td><td>1 x 10<\/td><td>0.7<\/td><td>1.4<\/td><td>8.3<\/td><td>146<\/td><td>1000<\/td><\/tr><tr><td>L222<\/td><td>U1L1-11500R-10002K-S<\/td><td>1 x 16<\/td><td>0.7<\/td><td>1.4<\/td><td>9.3<\/td><td>206<\/td><td>1000<\/td><\/tr><tr><td>L223<\/td><td>U1L1-11600C-10002K-S<\/td><td>1 x 25<\/td><td>0.9<\/td><td>1.4<\/td><td>10.6<\/td><td>300<\/td><td>1000<\/td><\/tr><tr><td>L224<\/td><td>U1L1-11700C-10002K-S<\/td><td>1 x 35<\/td><td>0.9<\/td><td>1.4<\/td><td>11.7<\/td><td>402<\/td><td>1000<\/td><\/tr><tr><td>L225<\/td><td>U1L1-11800C-10002K-S<\/td><td>1 x 50<\/td><td>1.0<\/td><td>1.4<\/td><td>13.2<\/td><td>530<\/td><td>1000<\/td><\/tr><tr><td>L226<\/td><td>U1L1-11900C-10002K-S<\/td><td>1 x 70<\/td><td>1.1<\/td><td>1.4<\/td><td>15.0<\/td><td>731<\/td><td>1000<\/td><\/tr><tr><td>L227<\/td><td>U1L1-12000C-10002K-S<\/td><td>1 x 95<\/td><td>1.1<\/td><td>1.5<\/td><td>16.8<\/td><td>996<\/td><td>1000<\/td><\/tr><tr><td>L228<\/td><td>U1L1-12100C-10002K-S<\/td><td>1 x 120<\/td><td>1.2<\/td><td>1.5<\/td><td>18.5<\/td><td>1225<\/td><td>1000<\/td><\/tr><tr><td>L229<\/td><td>U1L1-12200C-10002K-S<\/td><td>1 x 150<\/td><td>1.4<\/td><td>1.6<\/td><td>20.6<\/td><td>1537<\/td><td>1000<\/td><\/tr><tr><td>L230<\/td><td>U1L1-12300C-10002K-S<\/td><td>1 x 185<\/td><td>1.6<\/td><td>1.6<\/td><td>22.6<\/td><td>1888<\/td><td>1000<\/td><\/tr><tr><td>L231<\/td><td>U1L1-12400C-10002K-S<\/td><td>1 x 240<\/td><td>1.7<\/td><td>1.7<\/td><td>25.3<\/td><td>2466<\/td><td>1000<\/td><\/tr><tr><td>L232<\/td><td>U1L1-12500C-10002K-S<\/td><td>1 x 300<\/td><td>1.8<\/td><td>1.8<\/td><td>27.8<\/td><td>3040<\/td><td>500<\/td><\/tr><tr><td>L233<\/td><td>U1L1-12600C-10002K-S<\/td><td>1 x 400<\/td><td>2.0<\/td><td>1.9<\/td><td>31.6<\/td><td>3870<\/td><td>500<\/td><\/tr><tr><td>L234<\/td><td>U1L1-12700C-10002K-S<\/td><td>1 x 500<\/td><td>2.2<\/td><td>2.0<\/td><td>35.0<\/td><td>4892<\/td><td>500<\/td><\/tr><tr><td>L235<\/td><td>U1L1-12900C-10002K-S<\/td><td>1 x 630<\/td><td>2.4<\/td><td>2.2<\/td><td>39.1<\/td><td>6215<\/td><td>500<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">\u0643\u0627\u0628\u0644\u0627\u062a \u0646\u062d\u0627\u0633\u064a\u0629 \u0645\u0639\u0632\u0648\u0644\u0629 \u0628\u0645\u0627\u062f\u0629 XLPE (\u0645\u0633\u0644\u062d)<\/h2>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td>L306<\/td><td>U1L1-11800C-10222K-S<\/td><td>1 x 50<\/td><td>1.0<\/td><td>1.25<\/td><td>1.8<\/td><td>19<\/td><td>775<\/td><td>1000<\/td><\/tr><tr><td>L307<\/td><td>U1L1-11900C-10222K-S<\/td><td>1 x 70<\/td><td>1.1<\/td><td>1.25<\/td><td>1.8<\/td><td>21<\/td><td>1025<\/td><td>1000<\/td><\/tr><tr><td>L308<\/td><td>U1L1-12000C-10222K-S<\/td><td>1 x 95<\/td><td>1.1<\/td><td>1.25<\/td><td>1.8<\/td><td>22<\/td><td>1300<\/td><td>1000<\/td><\/tr><tr><td>L309<\/td><td>U1L1-12100C-10222K-S<\/td><td>1 x 120<\/td><td>1.2<\/td><td>1.60<\/td><td>1.8<\/td><td>25<\/td><td>1600<\/td><td>1000<\/td><\/tr><tr><td>L310<\/td><td>U1L1-12200C-10222K-S<\/td><td>1 x 150<\/td><td>1.4<\/td><td>1.60<\/td><td>1.8<\/td><td>27<\/td><td>1950<\/td><td>1000<\/td><\/tr><tr><td>L311<\/td><td>U1L1-12300C-10222K-S<\/td><td>1 x 185<\/td><td>1.6<\/td><td>1.60<\/td><td>1.8<\/td><td>29<\/td><td>2350<\/td><td>1000<\/td><\/tr><tr><td>L312<\/td><td>U1L1-12400C-10222K-S<\/td><td>1 x 240<\/td><td>1.7<\/td><td>1.60<\/td><td>1.9<\/td><td>31<\/td><td>2950<\/td><td>500<\/td><\/tr><tr><td>L313<\/td><td>U1L1-12500C-10222K-S<\/td><td>1 x 300<\/td><td>1.8<\/td><td>1.60<\/td><td>1.9<\/td><td>34<\/td><td>3550<\/td><td>500<\/td><\/tr><tr><td>L314<\/td><td>U1L1-12600C-10222K-S<\/td><td>1 x 400<\/td><td>2.0<\/td><td>2.00<\/td><td>2.1<\/td><td>39<\/td><td>4600<\/td><td>500<\/td><\/tr><tr><td>L315<\/td><td>U1L1-12700C-10222K-S<\/td><td>1 x 500<\/td><td>2.2<\/td><td>2.00<\/td><td>2.2<\/td><td>42<\/td><td>5700<\/td><td>500<\/td><\/tr><tr><td>L316<\/td><td>U1L1-12900C-10222K-S<\/td><td>1 x 630<\/td><td>2.4<\/td><td>2.00<\/td><td>2.3<\/td><td>46<\/td><td>7100<\/td><td>500<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">\u0643\u0627\u0628\u0644\u0627\u062a (ABC)<\/h2>\n\n\n\n<p><strong>NFC 33209 0.6\/1 kV Aerial bundled Cable ABC Cable<\/strong><br><br><strong>NFC 33209 0.6\/1kV Aerial bundle Cable&nbsp;ABC&nbsp;Cable&nbsp;XLPE Insulated Cable<\/strong><br><br><strong>ABC Cable Application<\/strong><\/p>\n\n\n\n<p>NFC 33209 0.6\/1kV&nbsp;Aerial bundle Cable&nbsp;ABC&nbsp;Cable&nbsp;XLPE Insulated Cable&nbsp;is&nbsp;the overhead insulated cable, used as public lighting wire or testing wire etc.<br><br>Aerial bunched cable 0.6\/1kV is extensively installed in&nbsp;urban and forest region which provides&nbsp;&nbsp;the safety and reliance&nbsp;for public power distribution network.<br><br><strong>ABC Cable Characteristics<\/strong><br><br>Rated Voltage Uo\/U (Um) :0.6\/1kV (1.2kV)<br>Temperature Rating: Operation temp.:90\u2103; Short Circuit Temp.:250\u2103<br>Minimum Bending Radius:Single core: 13\u00d7OD; Multi-core: 6\u00d7OD(min) while 12\u00d7OD during installation<br><br><strong>ABC Cable&nbsp;Construction<\/strong><br><br>Aerial Bundle Conductor(ABC)<br>Aerial Bundled Conductors (Phase Core): Circular, Class 2 stranded conductor, round compacted or non-compacted AAC conductor, AAAC conductor, or ACSR.<br><br>Aerial Bundled Conductor&nbsp;Messenger or Neutral Core:Circular, Class 2 stranded conductor, round compacted or non-compacted AAAC conductor (All Aluminium Alloy Conductor), AAC conductor(all aluminium conductor); ACSR conductor(Aluminium Conductor Steel Reinforced conductor),<br>Neutral Core Sizes: 54.6mm2, 70mm2, 95mm2<br><br>ABC Conductor Lighting Conductor:Circular, Class 2 stranded conductor, round compacted or non-compacted AAC conductor, AAAC conductor, or ACSR<br><br>Aluminium conductors ABC standard as per NF C 32-013, IEC 228 &amp; IEC 228A<br><br><strong>LV Aerial Bundled Cable Insulation<\/strong><br>Overhead Conductor (ABC) Insulation: Low Density Polyethylene (LDPE), High Density Polyethylene(HDPE), XLPE(cross-linked polyethylene ), Polyvinyl&nbsp;chloride(PVC).<br><br><strong>Aerial Bunch Cable&nbsp;Standard<\/strong><br><br>As one of leading&nbsp;ABC Cable suppliers, we produce aerial bunched cables meeting NFC 33029, IEC60228, NF C 32-013\uff0cNFC 32 013, AS\/NZS 3560.1,BS 7870-5,ANSI\/CEA S-76-474,NTP 370.254 etc<br><br>Low Voltage Aerial Bundle Cables Specification<br><br>Aerial Bundled Cable Size Without Messenger As Following:<\/p>\n\n\n\n<p>*&nbsp;&nbsp;&nbsp;2&nbsp;x&nbsp;16 mm2&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;* &nbsp;2 x 16 mm2&nbsp;+ 2 x 1.5 mm2&nbsp;&nbsp; &nbsp;&nbsp;<br>* &nbsp;&nbsp;2 x 25 mm2&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;* &nbsp;2 x 25 mm2&nbsp;+ 2 x 1.5 mm2<br>&nbsp;&nbsp;&nbsp;&nbsp;2 x 35 mm2&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;2 x 35 mm2 + 2 x 1.5 mm2<br>&nbsp;&nbsp;&nbsp;&nbsp;2 x 50 mm2&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;2 x 50 mm2&nbsp;+ 2 x&nbsp;1.5 mm2<br>* &nbsp;4 x 16 mm2&nbsp; &nbsp; &nbsp; &nbsp; &nbsp;* &nbsp;4 x 16 mm2&nbsp;+ 2 x 1.5 mm2<br>&nbsp; &nbsp;4 x 25 mm2&nbsp; &nbsp; &nbsp; &nbsp; &nbsp;* &nbsp;4 x 25 mm2&nbsp;+&nbsp;2 x 1.5 mm2<br>&nbsp; &nbsp;4 x 35 mm2&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;4 x&nbsp;35 mm2&nbsp;+&nbsp;2 x 1.5 mm2<br><br>LV Aerial Bundled Cable&nbsp;With Messenger Construction As Following:<\/p>\n\n\n\n<p>&nbsp; &nbsp; 1 x 54.6&nbsp;mm2&nbsp;+ 3 x 25&nbsp;mm2&nbsp;+ K x 16&nbsp;mm2<br>* &nbsp;&nbsp;1 x 54.6&nbsp;mm2&nbsp;+ 3 x 35&nbsp;mm2&nbsp;+&nbsp;K x 16&nbsp;mm2<br>&nbsp; &nbsp; 1 x 54.6&nbsp;mm2&nbsp;+ 3 x 50&nbsp;mm2&nbsp;+ K&nbsp;x 16&nbsp;mm2<br>&nbsp; &nbsp; 1 x 54.6&nbsp;mm2&nbsp;+ 3 x 70&nbsp;mm2&nbsp;+ K x 16&nbsp;mm2<br>&nbsp; &nbsp; 1 x 54.6&nbsp;mm2&nbsp;+&nbsp;3 x 70&nbsp;mm2&nbsp;+ K&nbsp;x&nbsp;25&nbsp;mm2<br>* &nbsp;&nbsp;1 x 70&nbsp;mm2+ 3 x 70&nbsp;mm2+ K x 16&nbsp;mm2<br>&nbsp; &nbsp; 1 x 70&nbsp;mm2+ 3 x 95&nbsp;mm2+ K x 16&nbsp;mm2<br>&nbsp; &nbsp; 1&nbsp;x&nbsp;70&nbsp;mm2+ 3 x 120&nbsp;mm2&nbsp;+&nbsp;K x 16&nbsp;mm2<br>* &nbsp;&nbsp;1 x 70&nbsp;mm2+ 3 x 120&nbsp;mm2+ K x 16&nbsp;mm2<br>&nbsp; &nbsp; 1&nbsp;x&nbsp;95&nbsp;mm2+ 3 x 120&nbsp;mm2+ K x 16&nbsp;mm2<br>&nbsp; &nbsp; 1 x 95&nbsp;mm2+ 3 x 150&nbsp;mm2+ K x 16&nbsp;mm2<br>Remark: K represents number of lighting core, which could be 0 core, 1 core,2 cores,3cores.<br><br><strong>Aerial Insulated Cable&nbsp;Technical Data<\/strong><\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td colspan=\"2\">Name<\/td><td colspan=\"5\">Conductor<\/td><td rowspan=\"2\">Average Thickness of Insulation<\/td><td colspan=\"2\">Lighting Wire<\/td><\/tr><tr><td>Category<\/td><td>Norm Cross-Section<\/td><td>No. Of Strand<\/td><td>DC Resistance<\/td><td colspan=\"2\">Conductor Diameter&nbsp;<\/td><td>Breaking Load<\/td><td colspan=\"2\">Overall Diameter<\/td><\/tr><tr><td>&nbsp;<\/td><td>&nbsp;<br>(mm2)<\/td><td>&nbsp;<\/td><td>20\u2103<br>(\u03a9\/km)<\/td><td>Min<br>(mm)<\/td><td>Max<br>(mm)<\/td><td>Min<br>(daN)<\/td><td>&nbsp;<br>(mm)<\/td><td>Min<br>(mm)<\/td><td>Maz<br>(mm)<\/td><\/tr><tr><td>Phase Core, neutral core(not messenger) or lighting core<br>&nbsp;<br>&nbsp;<\/td><td>16<br>25<br>35<br>&nbsp;<br>50<br>70<br>95<br>120<br>150<\/td><td>7<br>7<br>7<br>&nbsp;<br>7<br>12<br>19<br>19<br>19<\/td><td>1.91<br>1.20<br>0.868<br>&nbsp;<br>0.641<br>0.443<br>0.320<br>0.253<br>0.206<\/td><td>4.6<br>5.8<br>6.8<br>&nbsp;<br>7.9<br>9.7<br>11.0<br>12.0<br>13.9<\/td><td>5.1<br>6.3<br>7.3<br>&nbsp;<br>8.4<br>10.2<br>12.0<br>13.1<br>15.0<\/td><td>190<br>300<br>\u2013<br>&nbsp;<br>\u2013<br>\u2013<br>\u2013<br>\u2013<br>\u2013<\/td><td>1.2<br>1.4<br>1.6<br>&nbsp;<br>1.6<br>1.8<br>1.8<br>1.8<br>1.7<\/td><td>7.0<br>8.6<br>10.0<br>&nbsp;<br>11.1<br>13.3<br>14.6<br>15.6<br>17.3<\/td><td>7.8<br>9.4<br>10.9<br>&nbsp;<br>12.0<br>14.2<br>15.7<br>16.7<br>18.6<\/td><\/tr><tr><td>Messenger<\/td><td>54.6<br>70<br>95<\/td><td>7<br>7<br>19<\/td><td>0.63<br>0.50<br>0.343<\/td><td>9.2<br>10.0<br>12.2<\/td><td>9.6<br>10.2<br>12.9<\/td><td>1660<br>2050<br>2750<\/td><td>1.6<br>1.5<br>1.6<\/td><td>12.3<br>12.9<br>15.3**<\/td><td>13.0<br>13.6<br>16.3**<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p>1KV XLPE Insulation Overhead Cable&nbsp;Markings<br>Embossed, gravure or ink printed<br><br>Core Identification of Overhead Cable ABC cable<br><br>By Color Strip; By Number, By Rib.<\/p>\n\n\n\n<p>Reason to choose Dosense Cable as one of your Aerial Bunched Cable Manufacturers<\/p>","protected":false},"excerpt":{"rendered":"<p>Low voltage power cables are built to IEC and BS requirements, with a rated voltage of 0.6\/1KV.These cables are used to distribute electricity in metropolitan networks, industrial facilities, and electrical machinery.They are excellent for both indoor and outdoor applications, as well as moist and wet environments. Copper Conductor PVC Insulated Cable (Unarmoured) PVC Insulated, PVC Sheathed Unarmoured Cables CU \/ PVC \/ PVC Single Core Standard: IEC 60502-1 Conductor: Class 2 stranded copper as per IEC 60228, BS EN 60228. Rated Voltage: 0.6\/1 KV Insulation: PVC insulation type A as per IEC 60502-1 or type TI1 as per BS EN 50363temperature rating 70 oC.(PVC 90 oC is available on request). Shape of Conductor: 16 mm2 and below, conductor shall be circular stranded non-compacted.25 mm2 and above, conductor shall be circular stranded compacted. Outer Sheath: PVC outer sheath type ST1 as per IEC 60502-1 or type TM1 as per BS EN 50363. Applications: For outdoor and indoor installations in damp and wet locations. They are normally used for power distribution in urban networks, industrial plants and energy distribution. Order No. Item Code No. Nominal Area Nominal Insulation Thickness Nominal Outer Sheath Thickness Approx. Overall Diameter*&nbsp; Approx. Cable Weight**&nbsp; Standard Length No. x mm2 mm mm mm Kg\/Km (mtr. \u00b1 5%) L001 U1L1-11400R-20002K-S 1 x 10 1.0 1.4 9 175 1000 L002 U1L1-11500R-20002K-S 1 x 16 1.0 1.4 10 235 1000 L003 U1L1-11600C-20002K-S 1 x 25 1.2 1.4 12 330 1000 L004 U1L1-11700C-20002K-S 1 x 35 1.2 1.4 13 430 1000 L005 U1L1-11800C-20002K-S 1 x 50 1.4 1.4 14 575 1000 L006 U1L1-11900C-20002K-S 1 x 70 1.4 1.4 16 775 1000 L007 U1L1-12000C-20002K-S 1 x 95 1.6 1.5 18 1050 1000 L008 U1L1-12100C-20002K-S 1 x 120 1.6 1.5 20 1300 1000 L009 U1L1-12200C-20002K-S 1 x 150 1.8 1.6 22 1575 1000 L010 U1L1-12200C-20002K-S 1 x 185 2.0 1.7 24 1975 1000 L011 U1L1-12400C-20002K-S 1 x 240 2.2 1.8 27 2550 1000 L012 U1L1-12500C-20002K-S 1 x 300 2.4 1.9 30 3175&nbsp; 1000 L013 U1L1-12600C-20002K-S 1 x 400 2.6 2.0 33 4025 500 L014 U1L1-12700C-20002K-S 1 x 500 2.8 2.1 37 5100 500 L015 U1L1-12900C-20002K-S 1 x 630 2.8 2.2 41 6475 500 PVC Insulated, PVC Sheathed Unarmoured Cables CU \/ PVC \/ PVC Two Core Standard: IEC 60502-1 Conductor: Class 1 solid (up to 6 mm2upon request) copper or class 2 stranded copper as per IEC 60228,BS EN 60228. Rated Voltage: 0.6\/1 KV Insulation: PVC insulation type A as per IEC 60502-1 or type TI1 as per BS EN 50363temperature rating 70 oC.(PVC 90 oC is available on request). Shape of Conductor: 16 mm2 and below, conductor shall be circular stranded non-compacted.25 mm2 and above, conductor shall be circular stranded compacted. Outer Sheath: PVC outer sheath type ST1 as per IEC 60502-1 or type TM1 as per BS EN 50363. \ufeff \ufeff Applications: For outdoor and indoor installations in damp and wet locations. They are normally used for power distribution in urban networks, industrial plants and energy distribution. Order No. Item Code No. Nominal Area Nominal Insulation Thickness Nominal Outer Sheath Thickness Approx. Overall Diameter*&nbsp; Approx. Cable Weight**&nbsp; Standard Length No. x mm2 mm mm mm Kg\/Km (mtr. \u00b1 5%) L016 U1L1-20800R-20002K-S 2 x 1.5&nbsp; 0.8 1.8 10 150 1000 L017 U1L1-21000R-20002K-S 2 x 2.5 0.8 1.8 11 190 1000 L018 U1L1-21200R-20002K-S 2 x 4.0 1.0 1.8 13 260 1000 L019 U1L1-21300R-20002K-S 2 x 6.0 1.0 1.8 14 330 1000 L020 U1L1-21400R-20R02K-S 2 x 10 1.0 1.8 18 575 1000 L021 U1L1-21500R-20R02K-S 2 x 16 1.0 1.8 20 760 1000 L022 U1L1-21600C-20202K-S 2 x 25 1.2 1.8 23 975 1000 L023 U1L1-21700C-20202K-S 2 x 35 1.2 1.8 25 1250 1000 L024 U1L1-21800C-20202K-S 2 x 50 1.4 1.8 29 1650 1000 L025 U1L1-21900C-20202K-S 2 x 70 1.4 1.9 32 2225 500 L026 U1L1-22000C-20202K-S 2 x 95 1.6 2.0 37 2975 500 L027 U1L1-22100C-20202K-S 2 x 120 1.6 2.1 40 3575 500 L028 U1L1-22200C-20202K-S 2 x 150 1.8 2.2 44 4475 500 L029 U1L1-22300C-20202K-S 2 x 185 2.0 2.4 48 5475 500 L030 U1L1-22400C-20202K-S 2 x 240 2.2 2.6 55 7100 250 L031 U1L1-22500C-20202K-S 2 x 300 2.4 2.7 60 8700 250 PVC Insulated, PVC Sheathed Unarmoured Cables CU \/ PVC \/ PVC Three Core Standard: IEC 60502-1 Conductor: Class 1 solid (up to 6 mm2upon request) copper or class 2 stranded copper as per IEC 60228,BS EN 60228. Rated Voltage: 0.6\/1 KV Insulation: PVC insulation type A as per IEC 60502-1 or type TI1 as per BS EN 50363temperature rating 70 oC.(PVC 90 oC is available on request). Shape of Conductor: 16 mm2 and below, conductor shall be circular stranded non-compacted.25 mm2 and above, conductor shall be sectoral stranded compacted. Outer Sheath: PVC outer sheath type ST1 as per IEC 60502-1 or type TM1 as per BS EN 50363. \ufeff \ufeff Applications: For outdoor and indoor installations in damp and wet locations. They are normally used for power distribution in urban networks, industrial plants and energy distribution. Order No. Item Code No. Nominal Area Nominal Insulation Thickness Nominal Outer Sheath Thickness Approx. Overall Diameter*&nbsp; Approx. Cable Weight**&nbsp; Standard Length No. x mm2 mm mm mm Kg\/Km (mtr. \u00b1 5%) L032 U1L1-30800R-20002K-S 3 x 1.5 0.8 1.8 11 175 1000 L033 U1L1-31000R-20002K-S 3 x 2.5 0.8 1.8 12 225 1000 L034 U1L1-31200R-20002K-S 3 x 4.0 1.0 1.8 14 315 1000 L035 U1L1-31300R-20002K-S 3 x 6.0 1.0 1.8 15 400 1000 L036 U1L1-31400R-20R02K-S 3 x 10 1.0 1.8 19 675 1000 L037 U1L1-31500R-20R02K-S 3 x 16 1.0 1.8 20 925 1000 L038 U1L1-31600S-20002K-S 3 x 25 1.2 1.8 20 975 1000 L039 U1L1-31700S-20002K-S 3 x 35 1.2 1.8 22 1275 1000 L040 U1L1-31800S-20002K-S 3 x 50 1.4 1.8 25 1700 1000 L041 U1L1-31900S-20002K-S 3 x 70 1.4 1.9 28 2325 1000 L042 U1L1-32000S-20002K-S 3 x 95 1.6 2.1 32 3200 500 L043 U1L1-32100S-20002K-S 3 x 120 1.6 2.2 34 3900 500 L044 U1L1-32200S-20002K-S 3 x 150 1.8 2.3 38 4875 500 L045 U1L1-32300S-20002K-S 3 x 185 2.0 2.5 42 6025 500 L046 U1L1-32400S-20002K-S 3 x<\/p>","protected":false},"author":1,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"categories":[6],"tags":[],"class_list":["post-1787","post","type-post","status-publish","format-standard","hentry","category-products"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v24.3 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\r\n<title>Low Voltage Power Cables | Wadi Al Seer Cables<\/title>\r\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\r\n<link rel=\"canonical\" href=\"https:\/\/wadiseercables.com\/ar\/low-voltage-power-cables\/\" \/>\r\n<meta property=\"og:locale\" content=\"ar_AR\" \/>\r\n<meta property=\"og:type\" content=\"article\" \/>\r\n<meta property=\"og:title\" content=\"Low Voltage Power Cables | Wadi Al Seer Cables\" \/>\r\n<meta property=\"og:description\" content=\"Low voltage power cables are built to IEC and BS requirements, with a rated voltage of 0.6\/1KV.These cables are used to distribute electricity in metropolitan networks, industrial facilities, and electrical machinery.They are excellent for both indoor and outdoor applications, as well as moist and wet environments. Copper Conductor PVC Insulated Cable (Unarmoured) PVC Insulated, PVC Sheathed Unarmoured Cables CU \/ PVC \/ PVC Single Core Standard: IEC 60502-1 Conductor: Class 2 stranded copper as per IEC 60228, BS EN 60228. Rated Voltage: 0.6\/1 KV Insulation: PVC insulation type A as per IEC 60502-1 or type TI1 as per BS EN 50363temperature rating 70 oC.(PVC 90 oC is available on request). Shape of Conductor: 16 mm2 and below, conductor shall be circular stranded non-compacted.25 mm2 and above, conductor shall be circular stranded compacted. Outer Sheath: PVC outer sheath type ST1 as per IEC 60502-1 or type TM1 as per BS EN 50363. Applications: For outdoor and indoor installations in damp and wet locations. They are normally used for power distribution in urban networks, industrial plants and energy distribution. Order No. Item Code No. Nominal Area Nominal Insulation Thickness Nominal Outer Sheath Thickness Approx. Overall Diameter*&nbsp; Approx. Cable Weight**&nbsp; Standard Length No. x mm2 mm mm mm Kg\/Km (mtr. \u00b1 5%) L001 U1L1-11400R-20002K-S 1 x 10 1.0 1.4 9 175 1000 L002 U1L1-11500R-20002K-S 1 x 16 1.0 1.4 10 235 1000 L003 U1L1-11600C-20002K-S 1 x 25 1.2 1.4 12 330 1000 L004 U1L1-11700C-20002K-S 1 x 35 1.2 1.4 13 430 1000 L005 U1L1-11800C-20002K-S 1 x 50 1.4 1.4 14 575 1000 L006 U1L1-11900C-20002K-S 1 x 70 1.4 1.4 16 775 1000 L007 U1L1-12000C-20002K-S 1 x 95 1.6 1.5 18 1050 1000 L008 U1L1-12100C-20002K-S 1 x 120 1.6 1.5 20 1300 1000 L009 U1L1-12200C-20002K-S 1 x 150 1.8 1.6 22 1575 1000 L010 U1L1-12200C-20002K-S 1 x 185 2.0 1.7 24 1975 1000 L011 U1L1-12400C-20002K-S 1 x 240 2.2 1.8 27 2550 1000 L012 U1L1-12500C-20002K-S 1 x 300 2.4 1.9 30 3175&nbsp; 1000 L013 U1L1-12600C-20002K-S 1 x 400 2.6 2.0 33 4025 500 L014 U1L1-12700C-20002K-S 1 x 500 2.8 2.1 37 5100 500 L015 U1L1-12900C-20002K-S 1 x 630 2.8 2.2 41 6475 500 PVC Insulated, PVC Sheathed Unarmoured Cables CU \/ PVC \/ PVC Two Core Standard: IEC 60502-1 Conductor: Class 1 solid (up to 6 mm2upon request) copper or class 2 stranded copper as per IEC 60228,BS EN 60228. Rated Voltage: 0.6\/1 KV Insulation: PVC insulation type A as per IEC 60502-1 or type TI1 as per BS EN 50363temperature rating 70 oC.(PVC 90 oC is available on request). Shape of Conductor: 16 mm2 and below, conductor shall be circular stranded non-compacted.25 mm2 and above, conductor shall be circular stranded compacted. Outer Sheath: PVC outer sheath type ST1 as per IEC 60502-1 or type TM1 as per BS EN 50363. \ufeff \ufeff Applications: For outdoor and indoor installations in damp and wet locations. They are normally used for power distribution in urban networks, industrial plants and energy distribution. Order No. Item Code No. Nominal Area Nominal Insulation Thickness Nominal Outer Sheath Thickness Approx. Overall Diameter*&nbsp; Approx. Cable Weight**&nbsp; Standard Length No. x mm2 mm mm mm Kg\/Km (mtr. \u00b1 5%) L016 U1L1-20800R-20002K-S 2 x 1.5&nbsp; 0.8 1.8 10 150 1000 L017 U1L1-21000R-20002K-S 2 x 2.5 0.8 1.8 11 190 1000 L018 U1L1-21200R-20002K-S 2 x 4.0 1.0 1.8 13 260 1000 L019 U1L1-21300R-20002K-S 2 x 6.0 1.0 1.8 14 330 1000 L020 U1L1-21400R-20R02K-S 2 x 10 1.0 1.8 18 575 1000 L021 U1L1-21500R-20R02K-S 2 x 16 1.0 1.8 20 760 1000 L022 U1L1-21600C-20202K-S 2 x 25 1.2 1.8 23 975 1000 L023 U1L1-21700C-20202K-S 2 x 35 1.2 1.8 25 1250 1000 L024 U1L1-21800C-20202K-S 2 x 50 1.4 1.8 29 1650 1000 L025 U1L1-21900C-20202K-S 2 x 70 1.4 1.9 32 2225 500 L026 U1L1-22000C-20202K-S 2 x 95 1.6 2.0 37 2975 500 L027 U1L1-22100C-20202K-S 2 x 120 1.6 2.1 40 3575 500 L028 U1L1-22200C-20202K-S 2 x 150 1.8 2.2 44 4475 500 L029 U1L1-22300C-20202K-S 2 x 185 2.0 2.4 48 5475 500 L030 U1L1-22400C-20202K-S 2 x 240 2.2 2.6 55 7100 250 L031 U1L1-22500C-20202K-S 2 x 300 2.4 2.7 60 8700 250 PVC Insulated, PVC Sheathed Unarmoured Cables CU \/ PVC \/ PVC Three Core Standard: IEC 60502-1 Conductor: Class 1 solid (up to 6 mm2upon request) copper or class 2 stranded copper as per IEC 60228,BS EN 60228. Rated Voltage: 0.6\/1 KV Insulation: PVC insulation type A as per IEC 60502-1 or type TI1 as per BS EN 50363temperature rating 70 oC.(PVC 90 oC is available on request). Shape of Conductor: 16 mm2 and below, conductor shall be circular stranded non-compacted.25 mm2 and above, conductor shall be sectoral stranded compacted. Outer Sheath: PVC outer sheath type ST1 as per IEC 60502-1 or type TM1 as per BS EN 50363. \ufeff \ufeff Applications: For outdoor and indoor installations in damp and wet locations. They are normally used for power distribution in urban networks, industrial plants and energy distribution. Order No. Item Code No. Nominal Area Nominal Insulation Thickness Nominal Outer Sheath Thickness Approx. Overall Diameter*&nbsp; Approx. Cable Weight**&nbsp; Standard Length No. x mm2 mm mm mm Kg\/Km (mtr. \u00b1 5%) L032 U1L1-30800R-20002K-S 3 x 1.5 0.8 1.8 11 175 1000 L033 U1L1-31000R-20002K-S 3 x 2.5 0.8 1.8 12 225 1000 L034 U1L1-31200R-20002K-S 3 x 4.0 1.0 1.8 14 315 1000 L035 U1L1-31300R-20002K-S 3 x 6.0 1.0 1.8 15 400 1000 L036 U1L1-31400R-20R02K-S 3 x 10 1.0 1.8 19 675 1000 L037 U1L1-31500R-20R02K-S 3 x 16 1.0 1.8 20 925 1000 L038 U1L1-31600S-20002K-S 3 x 25 1.2 1.8 20 975 1000 L039 U1L1-31700S-20002K-S 3 x 35 1.2 1.8 22 1275 1000 L040 U1L1-31800S-20002K-S 3 x 50 1.4 1.8 25 1700 1000 L041 U1L1-31900S-20002K-S 3 x 70 1.4 1.9 28 2325 1000 L042 U1L1-32000S-20002K-S 3 x 95 1.6 2.1 32 3200 500 L043 U1L1-32100S-20002K-S 3 x 120 1.6 2.2 34 3900 500 L044 U1L1-32200S-20002K-S 3 x 150 1.8 2.3 38 4875 500 L045 U1L1-32300S-20002K-S 3 x 185 2.0 2.5 42 6025 500 L046 U1L1-32400S-20002K-S 3 x\" \/>\r\n<meta property=\"og:url\" content=\"https:\/\/wadiseercables.com\/ar\/low-voltage-power-cables\/\" \/>\r\n<meta property=\"og:site_name\" content=\"Wadi Al Seer Cables\" \/>\r\n<meta property=\"article:published_time\" content=\"2025-02-04T07:51:26+00:00\" \/>\r\n<meta property=\"article:modified_time\" content=\"2025-02-04T08:06:32+00:00\" \/>\r\n<meta property=\"og:image\" content=\"https:\/\/web.archive.org\/web\/20240913110739im_\/https:\/\/wadiseercables.com\/wp-content\/uploads\/2024\/07\/image-removebg-preview-2024-07-17T204317.749.png\" \/>\r\n<meta name=\"author\" content=\"wadiseercables\" \/>\r\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\r\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"wadiseercables\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"20 minutes\" \/>\r\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\/\/wadiseercables.com\/low-voltage-power-cables\/#article\",\"isPartOf\":{\"@id\":\"https:\/\/wadiseercables.com\/low-voltage-power-cables\/\"},\"author\":{\"name\":\"wadiseercables\",\"@id\":\"https:\/\/wadiseercables.com\/#\/schema\/person\/ed581db9e1b98bb3d37142acb97e7be3\"},\"headline\":\"Low Voltage Power Cables\",\"datePublished\":\"2025-02-04T07:51:26+00:00\",\"dateModified\":\"2025-02-04T08:06:32+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\/\/wadiseercables.com\/low-voltage-power-cables\/\"},\"wordCount\":3643,\"commentCount\":0,\"publisher\":{\"@id\":\"https:\/\/wadiseercables.com\/#organization\"},\"image\":{\"@id\":\"https:\/\/wadiseercables.com\/low-voltage-power-cables\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/web.archive.org\/web\/20240913110739im_\/https:\/\/wadiseercables.com\/wp-content\/uploads\/2024\/07\/image-removebg-preview-2024-07-17T204317.749.png\",\"articleSection\":[\"Products\"],\"inLanguage\":\"ar\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\/\/wadiseercables.com\/low-voltage-power-cables\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/wadiseercables.com\/low-voltage-power-cables\/\",\"url\":\"https:\/\/wadiseercables.com\/low-voltage-power-cables\/\",\"name\":\"Low Voltage Power Cables | Wadi Al Seer Cables\",\"isPartOf\":{\"@id\":\"https:\/\/wadiseercables.com\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/wadiseercables.com\/low-voltage-power-cables\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/wadiseercables.com\/low-voltage-power-cables\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/web.archive.org\/web\/20240913110739im_\/https:\/\/wadiseercables.com\/wp-content\/uploads\/2024\/07\/image-removebg-preview-2024-07-17T204317.749.png\",\"datePublished\":\"2025-02-04T07:51:26+00:00\",\"dateModified\":\"2025-02-04T08:06:32+00:00\",\"breadcrumb\":{\"@id\":\"https:\/\/wadiseercables.com\/low-voltage-power-cables\/#breadcrumb\"},\"inLanguage\":\"ar\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/wadiseercables.com\/low-voltage-power-cables\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"ar\",\"@id\":\"https:\/\/wadiseercables.com\/low-voltage-power-cables\/#primaryimage\",\"url\":\"https:\/\/web.archive.org\/web\/20240913110739im_\/https:\/\/wadiseercables.com\/wp-content\/uploads\/2024\/07\/image-removebg-preview-2024-07-17T204317.749.png\",\"contentUrl\":\"https:\/\/web.archive.org\/web\/20240913110739im_\/https:\/\/wadiseercables.com\/wp-content\/uploads\/2024\/07\/image-removebg-preview-2024-07-17T204317.749.png\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/wadiseercables.com\/low-voltage-power-cables\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/wadiseercables.com\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Low Voltage Power Cables\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/wadiseercables.com\/#website\",\"url\":\"https:\/\/wadiseercables.com\/\",\"name\":\"Wadi Al Seer Cables\",\"description\":\"For Producing Jordanian Cables Company\",\"publisher\":{\"@id\":\"https:\/\/wadiseercables.com\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/wadiseercables.com\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"ar\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/wadiseercables.com\/#organization\",\"name\":\"Wadi Al Seer Cables\",\"url\":\"https:\/\/wadiseercables.com\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"ar\",\"@id\":\"https:\/\/wadiseercables.com\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/wadiseercables.com\/wp-content\/uploads\/2025\/01\/\u0634\u0639\u0627\u0631-\u0627\u0644\u0634\u0631\u0643\u0629-1-e1738485788779.png\",\"contentUrl\":\"https:\/\/wadiseercables.com\/wp-content\/uploads\/2025\/01\/\u0634\u0639\u0627\u0631-\u0627\u0644\u0634\u0631\u0643\u0629-1-e1738485788779.png\",\"width\":480,\"height\":430,\"caption\":\"Wadi Al Seer Cables\"},\"image\":{\"@id\":\"https:\/\/wadiseercables.com\/#\/schema\/logo\/image\/\"}},{\"@type\":\"Person\",\"@id\":\"https:\/\/wadiseercables.com\/#\/schema\/person\/ed581db9e1b98bb3d37142acb97e7be3\",\"name\":\"wadiseercables\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"ar\",\"@id\":\"https:\/\/wadiseercables.com\/#\/schema\/person\/image\/\",\"url\":\"https:\/\/secure.gravatar.com\/avatar\/638e4930bea9c711073d1050f2cfd1e5ceddb0913779d9ba76d40e15301469f3?s=96&d=mm&r=g\",\"contentUrl\":\"https:\/\/secure.gravatar.com\/avatar\/638e4930bea9c711073d1050f2cfd1e5ceddb0913779d9ba76d40e15301469f3?s=96&d=mm&r=g\",\"caption\":\"wadiseercables\"},\"sameAs\":[\"https:\/\/wadiseercables.com\"]}]}<\/script>\r\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Low Voltage Power Cables | Wadi Al Seer Cables","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/wadiseercables.com\/ar\/low-voltage-power-cables\/","og_locale":"ar_AR","og_type":"article","og_title":"Low Voltage Power Cables | Wadi Al Seer Cables","og_description":"Low voltage power cables are built to IEC and BS requirements, with a rated voltage of 0.6\/1KV.These cables are used to distribute electricity in metropolitan networks, industrial facilities, and electrical machinery.They are excellent for both indoor and outdoor applications, as well as moist and wet environments. Copper Conductor PVC Insulated Cable (Unarmoured) PVC Insulated, PVC Sheathed Unarmoured Cables CU \/ PVC \/ PVC Single Core Standard: IEC 60502-1 Conductor: Class 2 stranded copper as per IEC 60228, BS EN 60228. Rated Voltage: 0.6\/1 KV Insulation: PVC insulation type A as per IEC 60502-1 or type TI1 as per BS EN 50363temperature rating 70 oC.(PVC 90 oC is available on request). Shape of Conductor: 16 mm2 and below, conductor shall be circular stranded non-compacted.25 mm2 and above, conductor shall be circular stranded compacted. Outer Sheath: PVC outer sheath type ST1 as per IEC 60502-1 or type TM1 as per BS EN 50363. Applications: For outdoor and indoor installations in damp and wet locations. They are normally used for power distribution in urban networks, industrial plants and energy distribution. Order No. Item Code No. Nominal Area Nominal Insulation Thickness Nominal Outer Sheath Thickness Approx. Overall Diameter*&nbsp; Approx. Cable Weight**&nbsp; Standard Length No. x mm2 mm mm mm Kg\/Km (mtr. \u00b1 5%) L001 U1L1-11400R-20002K-S 1 x 10 1.0 1.4 9 175 1000 L002 U1L1-11500R-20002K-S 1 x 16 1.0 1.4 10 235 1000 L003 U1L1-11600C-20002K-S 1 x 25 1.2 1.4 12 330 1000 L004 U1L1-11700C-20002K-S 1 x 35 1.2 1.4 13 430 1000 L005 U1L1-11800C-20002K-S 1 x 50 1.4 1.4 14 575 1000 L006 U1L1-11900C-20002K-S 1 x 70 1.4 1.4 16 775 1000 L007 U1L1-12000C-20002K-S 1 x 95 1.6 1.5 18 1050 1000 L008 U1L1-12100C-20002K-S 1 x 120 1.6 1.5 20 1300 1000 L009 U1L1-12200C-20002K-S 1 x 150 1.8 1.6 22 1575 1000 L010 U1L1-12200C-20002K-S 1 x 185 2.0 1.7 24 1975 1000 L011 U1L1-12400C-20002K-S 1 x 240 2.2 1.8 27 2550 1000 L012 U1L1-12500C-20002K-S 1 x 300 2.4 1.9 30 3175&nbsp; 1000 L013 U1L1-12600C-20002K-S 1 x 400 2.6 2.0 33 4025 500 L014 U1L1-12700C-20002K-S 1 x 500 2.8 2.1 37 5100 500 L015 U1L1-12900C-20002K-S 1 x 630 2.8 2.2 41 6475 500 PVC Insulated, PVC Sheathed Unarmoured Cables CU \/ PVC \/ PVC Two Core Standard: IEC 60502-1 Conductor: Class 1 solid (up to 6 mm2upon request) copper or class 2 stranded copper as per IEC 60228,BS EN 60228. Rated Voltage: 0.6\/1 KV Insulation: PVC insulation type A as per IEC 60502-1 or type TI1 as per BS EN 50363temperature rating 70 oC.(PVC 90 oC is available on request). Shape of Conductor: 16 mm2 and below, conductor shall be circular stranded non-compacted.25 mm2 and above, conductor shall be circular stranded compacted. Outer Sheath: PVC outer sheath type ST1 as per IEC 60502-1 or type TM1 as per BS EN 50363. \ufeff \ufeff Applications: For outdoor and indoor installations in damp and wet locations. They are normally used for power distribution in urban networks, industrial plants and energy distribution. Order No. Item Code No. Nominal Area Nominal Insulation Thickness Nominal Outer Sheath Thickness Approx. Overall Diameter*&nbsp; Approx. Cable Weight**&nbsp; Standard Length No. x mm2 mm mm mm Kg\/Km (mtr. \u00b1 5%) L016 U1L1-20800R-20002K-S 2 x 1.5&nbsp; 0.8 1.8 10 150 1000 L017 U1L1-21000R-20002K-S 2 x 2.5 0.8 1.8 11 190 1000 L018 U1L1-21200R-20002K-S 2 x 4.0 1.0 1.8 13 260 1000 L019 U1L1-21300R-20002K-S 2 x 6.0 1.0 1.8 14 330 1000 L020 U1L1-21400R-20R02K-S 2 x 10 1.0 1.8 18 575 1000 L021 U1L1-21500R-20R02K-S 2 x 16 1.0 1.8 20 760 1000 L022 U1L1-21600C-20202K-S 2 x 25 1.2 1.8 23 975 1000 L023 U1L1-21700C-20202K-S 2 x 35 1.2 1.8 25 1250 1000 L024 U1L1-21800C-20202K-S 2 x 50 1.4 1.8 29 1650 1000 L025 U1L1-21900C-20202K-S 2 x 70 1.4 1.9 32 2225 500 L026 U1L1-22000C-20202K-S 2 x 95 1.6 2.0 37 2975 500 L027 U1L1-22100C-20202K-S 2 x 120 1.6 2.1 40 3575 500 L028 U1L1-22200C-20202K-S 2 x 150 1.8 2.2 44 4475 500 L029 U1L1-22300C-20202K-S 2 x 185 2.0 2.4 48 5475 500 L030 U1L1-22400C-20202K-S 2 x 240 2.2 2.6 55 7100 250 L031 U1L1-22500C-20202K-S 2 x 300 2.4 2.7 60 8700 250 PVC Insulated, PVC Sheathed Unarmoured Cables CU \/ PVC \/ PVC Three Core Standard: IEC 60502-1 Conductor: Class 1 solid (up to 6 mm2upon request) copper or class 2 stranded copper as per IEC 60228,BS EN 60228. Rated Voltage: 0.6\/1 KV Insulation: PVC insulation type A as per IEC 60502-1 or type TI1 as per BS EN 50363temperature rating 70 oC.(PVC 90 oC is available on request). Shape of Conductor: 16 mm2 and below, conductor shall be circular stranded non-compacted.25 mm2 and above, conductor shall be sectoral stranded compacted. Outer Sheath: PVC outer sheath type ST1 as per IEC 60502-1 or type TM1 as per BS EN 50363. \ufeff \ufeff Applications: For outdoor and indoor installations in damp and wet locations. They are normally used for power distribution in urban networks, industrial plants and energy distribution. Order No. Item Code No. Nominal Area Nominal Insulation Thickness Nominal Outer Sheath Thickness Approx. Overall Diameter*&nbsp; Approx. Cable Weight**&nbsp; Standard Length No. x mm2 mm mm mm Kg\/Km (mtr. \u00b1 5%) L032 U1L1-30800R-20002K-S 3 x 1.5 0.8 1.8 11 175 1000 L033 U1L1-31000R-20002K-S 3 x 2.5 0.8 1.8 12 225 1000 L034 U1L1-31200R-20002K-S 3 x 4.0 1.0 1.8 14 315 1000 L035 U1L1-31300R-20002K-S 3 x 6.0 1.0 1.8 15 400 1000 L036 U1L1-31400R-20R02K-S 3 x 10 1.0 1.8 19 675 1000 L037 U1L1-31500R-20R02K-S 3 x 16 1.0 1.8 20 925 1000 L038 U1L1-31600S-20002K-S 3 x 25 1.2 1.8 20 975 1000 L039 U1L1-31700S-20002K-S 3 x 35 1.2 1.8 22 1275 1000 L040 U1L1-31800S-20002K-S 3 x 50 1.4 1.8 25 1700 1000 L041 U1L1-31900S-20002K-S 3 x 70 1.4 1.9 28 2325 1000 L042 U1L1-32000S-20002K-S 3 x 95 1.6 2.1 32 3200 500 L043 U1L1-32100S-20002K-S 3 x 120 1.6 2.2 34 3900 500 L044 U1L1-32200S-20002K-S 3 x 150 1.8 2.3 38 4875 500 L045 U1L1-32300S-20002K-S 3 x 185 2.0 2.5 42 6025 500 L046 U1L1-32400S-20002K-S 3 x","og_url":"https:\/\/wadiseercables.com\/ar\/low-voltage-power-cables\/","og_site_name":"Wadi Al Seer Cables","article_published_time":"2025-02-04T07:51:26+00:00","article_modified_time":"2025-02-04T08:06:32+00:00","og_image":[{"url":"https:\/\/web.archive.org\/web\/20240913110739im_\/https:\/\/wadiseercables.com\/wp-content\/uploads\/2024\/07\/image-removebg-preview-2024-07-17T204317.749.png","type":"","width":"","height":""}],"author":"wadiseercables","twitter_card":"summary_large_image","twitter_misc":{"Written by":"wadiseercables","Est. reading time":"20 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/wadiseercables.com\/low-voltage-power-cables\/#article","isPartOf":{"@id":"https:\/\/wadiseercables.com\/low-voltage-power-cables\/"},"author":{"name":"wadiseercables","@id":"https:\/\/wadiseercables.com\/#\/schema\/person\/ed581db9e1b98bb3d37142acb97e7be3"},"headline":"Low Voltage Power Cables","datePublished":"2025-02-04T07:51:26+00:00","dateModified":"2025-02-04T08:06:32+00:00","mainEntityOfPage":{"@id":"https:\/\/wadiseercables.com\/low-voltage-power-cables\/"},"wordCount":3643,"commentCount":0,"publisher":{"@id":"https:\/\/wadiseercables.com\/#organization"},"image":{"@id":"https:\/\/wadiseercables.com\/low-voltage-power-cables\/#primaryimage"},"thumbnailUrl":"https:\/\/web.archive.org\/web\/20240913110739im_\/https:\/\/wadiseercables.com\/wp-content\/uploads\/2024\/07\/image-removebg-preview-2024-07-17T204317.749.png","articleSection":["Products"],"inLanguage":"ar","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/wadiseercables.com\/low-voltage-power-cables\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/wadiseercables.com\/low-voltage-power-cables\/","url":"https:\/\/wadiseercables.com\/low-voltage-power-cables\/","name":"Low Voltage Power Cables | Wadi Al Seer Cables","isPartOf":{"@id":"https:\/\/wadiseercables.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/wadiseercables.com\/low-voltage-power-cables\/#primaryimage"},"image":{"@id":"https:\/\/wadiseercables.com\/low-voltage-power-cables\/#primaryimage"},"thumbnailUrl":"https:\/\/web.archive.org\/web\/20240913110739im_\/https:\/\/wadiseercables.com\/wp-content\/uploads\/2024\/07\/image-removebg-preview-2024-07-17T204317.749.png","datePublished":"2025-02-04T07:51:26+00:00","dateModified":"2025-02-04T08:06:32+00:00","breadcrumb":{"@id":"https:\/\/wadiseercables.com\/low-voltage-power-cables\/#breadcrumb"},"inLanguage":"ar","potentialAction":[{"@type":"ReadAction","target":["https:\/\/wadiseercables.com\/low-voltage-power-cables\/"]}]},{"@type":"ImageObject","inLanguage":"ar","@id":"https:\/\/wadiseercables.com\/low-voltage-power-cables\/#primaryimage","url":"https:\/\/web.archive.org\/web\/20240913110739im_\/https:\/\/wadiseercables.com\/wp-content\/uploads\/2024\/07\/image-removebg-preview-2024-07-17T204317.749.png","contentUrl":"https:\/\/web.archive.org\/web\/20240913110739im_\/https:\/\/wadiseercables.com\/wp-content\/uploads\/2024\/07\/image-removebg-preview-2024-07-17T204317.749.png"},{"@type":"BreadcrumbList","@id":"https:\/\/wadiseercables.com\/low-voltage-power-cables\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/wadiseercables.com\/"},{"@type":"ListItem","position":2,"name":"Low Voltage Power Cables"}]},{"@type":"WebSite","@id":"https:\/\/wadiseercables.com\/#website","url":"https:\/\/wadiseercables.com\/","name":"Wadi Al Seer Cables","description":"For Producing Jordanian Cables Company","publisher":{"@id":"https:\/\/wadiseercables.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/wadiseercables.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"ar"},{"@type":"Organization","@id":"https:\/\/wadiseercables.com\/#organization","name":"Wadi Al Seer Cables","url":"https:\/\/wadiseercables.com\/","logo":{"@type":"ImageObject","inLanguage":"ar","@id":"https:\/\/wadiseercables.com\/#\/schema\/logo\/image\/","url":"https:\/\/wadiseercables.com\/wp-content\/uploads\/2025\/01\/\u0634\u0639\u0627\u0631-\u0627\u0644\u0634\u0631\u0643\u0629-1-e1738485788779.png","contentUrl":"https:\/\/wadiseercables.com\/wp-content\/uploads\/2025\/01\/\u0634\u0639\u0627\u0631-\u0627\u0644\u0634\u0631\u0643\u0629-1-e1738485788779.png","width":480,"height":430,"caption":"Wadi Al Seer Cables"},"image":{"@id":"https:\/\/wadiseercables.com\/#\/schema\/logo\/image\/"}},{"@type":"Person","@id":"https:\/\/wadiseercables.com\/#\/schema\/person\/ed581db9e1b98bb3d37142acb97e7be3","name":"wadiseercables","image":{"@type":"ImageObject","inLanguage":"ar","@id":"https:\/\/wadiseercables.com\/#\/schema\/person\/image\/","url":"https:\/\/secure.gravatar.com\/avatar\/638e4930bea9c711073d1050f2cfd1e5ceddb0913779d9ba76d40e15301469f3?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/638e4930bea9c711073d1050f2cfd1e5ceddb0913779d9ba76d40e15301469f3?s=96&d=mm&r=g","caption":"wadiseercables"},"sameAs":["https:\/\/wadiseercables.com"]}]}},"_links":{"self":[{"href":"https:\/\/wadiseercables.com\/ar\/wp-json\/wp\/v2\/posts\/1787","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/wadiseercables.com\/ar\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/wadiseercables.com\/ar\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/wadiseercables.com\/ar\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/wadiseercables.com\/ar\/wp-json\/wp\/v2\/comments?post=1787"}],"version-history":[{"count":1,"href":"https:\/\/wadiseercables.com\/ar\/wp-json\/wp\/v2\/posts\/1787\/revisions"}],"predecessor-version":[{"id":1788,"href":"https:\/\/wadiseercables.com\/ar\/wp-json\/wp\/v2\/posts\/1787\/revisions\/1788"}],"wp:attachment":[{"href":"https:\/\/wadiseercables.com\/ar\/wp-json\/wp\/v2\/media?parent=1787"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/wadiseercables.com\/ar\/wp-json\/wp\/v2\/categories?post=1787"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/wadiseercables.com\/ar\/wp-json\/wp\/v2\/tags?post=1787"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}