Domestic Wires

Domestic wires are made to meet BS, IEC, and UL regulations, with a rated voltage of up to 450/750 volts.
These cables are used for internal siminsagh wiring in structures and electrical equipment.
They are appropriate for both fixed and transportable interior installations.


300/500 Volts – Copper Conductor PVC Insulated

Standard: BS 6004Conductor:Class 1 solid copper, class 2 stranded copper or class 5 flexible copper as per IEC 60228, BS EN 60228
Rated Voltage: 300/500 VInsulation: PVC Insulation type TI1 as per BS EN 50363,
PVC/C as per IEC 60227
temperature rating 70 ºC.
(PVC 90 ºC or 105 ºC available on request).
Harmonized Code: Solid conductor HO5V-U
Stranded conductor HO5V-R
Flexible conductor HO5V-K
Applications:Fixed protected installation inside the appliances and in or on light fitting.
Type of ConductorOrder No.Item Code No.Nominal AreaInsulation ThicknessApprox. Overall Diameter *Approx Weight **Standard LengthStandard Packing
mm²mmmmkg/kmm tr.
SolidT001U1T2-10400E-20000x-40.50.62.09.091.4Coil
T002U1T2-10500E-20000x-40.750.62.212.091.4Coil
T003U1T2-10600E-20000x-41.00.62.414.091.4Coil
StrandedT004U1T2-10400R-20000x-40.50.62.211.091.4Coil
T005U1T2-10500R-20000x-40.750.62.413.091.4Coil
T006U1T2-10600R-20000x-41.00.62.615.091.4Coil
FlexibleT007U1T2-10400F-20000x-40.50.62.110.091.4Coil
T008U1T2-10500F-20000x-40.750.62.312.091.4Coil
T009U1T2-10600F-20000x-41.00.62.514.091.4Coil
  • The Approx. overall diameter is subject to a tolerance of (-2/+8)%.
  • The Approx. weight is subject to a tolerance of ± 5%.

Features:

  • Small diameter saves space.
  • Excellent electric characteristics and mechanical strength.

450/750 Volts – Copper Conductor PVC Insulated

Standard:BS 6004, IEC 60227Conductor:Class 1 solid copper, class 2 stranded copper as per IEC 60228, BS EN 60228.
Rated Voltage:450/750 VInsulation:PVC Insulation type TI1 as per BS EN 50363,
PVC/C as per IEC 60227
temperature rating 70 ºC.
(PVC 90 ºC or 105 ºC available on request).
Harmonized Code:Solid conductor HO7V-U
Stranded conductor HO7V-R
Applications:Fixed installation in dry or damp premises. Suitabel in walls or boards and in channel or embadded in plaster.
Type of ConductorOrder No.Item Code No.Nominal AreaInsulation ThicknessApprox. Overall Diameter *Approx Weight **Standard LengthStandard Packing
mm²mmmmkg/kmm tr.
SolidW001U1W2-10800E-20000x-41.50.72.821.191.4Coil
W002U1W2-11000E-20000x-42.50.83.433.191.4Coil
W003U1W2-11200E-20000x-440.83.947.091.4Coil
W004U1W2-11300E-20000x-460.84.465.091.4Coil
W005U1W2-11400E-20000x-4101.05.6107.091.4Coil
StrandedW006U1W2-10800R-20000x-41.50.73.021.091.4Coil
W007U1W2-11000R-20000x-42.50.83.634.091.4Coil
W008U1W2-11200R-20000x-440.84.248.091.4Coil
W009U1W2-11300R-20000x-460.84.768.091.4Coil
W0010U1W2-11400R-20000x-4101.06.1112.091.4Coil
W0011U1W2-11500R-20000x-4161.07.1 169.091.4Coil
W0012U1W2-11600C-20000x-4251.28.4260.091.4Coil
W0013U1W2-11700C-20000x-4351.2 9.4355.091.4Coil
W0014U1W2-11800C-20000x-A501.410.9480.01000Drum
W0015U1W2-11900C-20000x-A701.412.5 670.01000Drum
W0016U1W2-12000C-20000x-A951.614.6935.01000Drum
W0017U1W2-12100C-20000x-A1201.616.1 1155.01000Drum
W0018U1W2-12200C-20000x-A1501.817.91455.01000Drum
W0019U1W2-12300C-20000x-A1852.0 20.01800.01000Drum
W0020U1W2-12400C-20000x-A2402.222.82355.01000Drum
W0021U1W2-12500C-20000x-A3002.425.22945.01000Drum
W0022U1W2-12600C-20000x-94002.628.43745.0500Drum
W0023U1W2-12700C-20000x-95002.832.34755.0500Drum
W0024U1W2-12900C-20000x-96302.836.06025.0500Drum
  • The Approx. overall diameter is subject to a tolerance of (-2/+8)%.
  • The Approx. weight is subject to a tolerance of ± 5%.

Features:

  • Small diameter saves space.
  • Excellent electric characteristics and mechanical strength.
Standard:BS 6004, IEC 60227Conductor:Class 5 flexible copper as per IEC 60228,
BS EN 60228.
Rated Voltage:450/750 VInsulation:PVC Insulation type TI1 as per BS EN 50363,
PVC/C as per IEC 60227
temperature rating 70 ºC.
(PVC 90 ºC or 105 ºC available on request).
Harmonized Code:Flexible conductor HO7V-KApplications:Suitable for use in channels with cover and for fixed protected installation in or on light fittings and inside applicances, switchgear and controlgear for voltages up to 1000V a.c. or up to 750V d.c. to earth.
Order No.Item Code No.Nominal AreaInsulation ThicknessApprox. Overall Diameter *Approx Weight **Standard LengthStandard Packing
mm²mmmmkg/kmm tr.
W025U1W2-10800F-20000x-41.50.73.021.091.4Coil
W026U1W2-11000F-20000x-42.50.83.532.091.4Coil
W027U1W2-11200F-20000x-440.84.148.091.4Coil
W028U1W2-11300F-20000x-460.84.768.091.4Coil
W029U1W2-11400F-20000x-4101.05.9115.091.4Coil
W030U1W2-11500F-20000x-4161.06.9167.091.4Coil
W031U1W2-11600F-20000x-4251.28.9255.091.4Coil
W032U1W2-11700F-20000x-4351.210.4360.091.4Coil
W033U1W2-11800F-20000x-A501.412.0495.01000Drum
W034U1W2-11900F-20000x-A701.413.8685.01000Drum
W035U1W2-12000F-20000x-A951.615.8900.01000Drum
W036U1W2-12100F-20000x-A 1201.617.31115.01000Drum
W037U1W2-12200F-20000x-A1501.820.11415.01000Drum
W038U1W2-12300F-20000x-A1852.021.81800.01000Drum
W039U1W2-12400F-20000x-A2402.224.82320.0 1000Drum
  • The Approx. overall diameter is subject to a tolerance of (-2/+8)%.
  • The Approx. weight is subject to a tolerance of ± 5%.

Features:

  • Extra-slide properties and excellent flexibility.

300/500 Volts – PVC Insulated PVC Sheathed Flat Cables

Standard:BS 6004Conductor:Class 1 solid copper, class 2 stranded copper as per IEC 60228, BS EN 60228.
Rated Voltage:300/500 VInsulation:PVC Insulation type TI1 as per BS EN 50363.
PVC type 6 as per BS EN 50363
(PVC 90 ºC or 105 ºC available on request).
Harmonized Code:Flexible conductor HO7V-KApplications:Fixed installation in dry or damp premises. Suitable for installation in walls, on boards and in channels or embedded in plaster.


Order No.
 
 Item Code No.
Nominal Area
Insulation ThicknessNominal Sheath ThicknessApprox. Overall Dimensions *Approx Weight **Standard Length

Standard Packing
No. x mm2mmmmmmKg/Kmmtr
T010U1T2-20600R-20002D-42 x 1.00.60.94.4 x 6.953.091.4Coil 
T011 U1T2-20800R-20002D-42 x 1.50.70.94.8 x 7.870.091.4Coil 
T012U1T2-21000R-20002D-42 x 2.50.81.05.6 x 9.2104.091.4Coil 
T013U1T2-21200R-20002D-42 x 4.00.81.06.2 x 10.3140.091.4Coil 
T014U1T2-21300R-20002D-42 x 6.00.81.07.0 x 11.7191.091.4Coil 
T015U1T2-21400R-20002D-42 x 101.01.28.5 x 14.5303.091.4Coil 
T016U1T2-30600R-20002D-43 x 1.00.60.94.4 x 9.476.091.4Coil 
T017U1T2-30800R-20002D-43 x 1.50.70.94.8 x 10.8102.091.4Coil 
T018U1T2-31000R-20002D-43 x 2.50.81.05.6 x 12.8149.091.4Coil 
T019U1T2-31200R-20002D-43 x 4.00.81.06.4 x 14.7210.091.4Coil 
T020U1T2-31300R-20002D-43 x 6.00.81.07.0 x 16.4265.091.4Coil 

Note: Items T010 and T016 are not covered by BS 6004; however, UCIC produces them as per this standard.

  • The Approx. overall diameter is subject to a tolerance of (-2/+8)%.
  • The Approx. weight is subject to a tolerance of ± 5%.

Features:

  • Small diameter saves space.
  • Flat shape saves places.

Core identification :

  • Two Cores: Brown, Blue.
  • Three Cores: Brown, Black, Grey.

300/300 Volts Light & 300/500 Volts Ordinary – PVC Insulated PVC Sheathed Flexible Cables

Standard:BS 6500Conductor:Class 5 Flexible copper as per IEC 60228, BS EN 60228.
Rated Voltage:Light PVC 300/300 V
Ordinary PVC 300/500 V
Insulation:PVC Insulation type TI2 as per BS EN 50363.
temperature rating 70 ºC.
Harmonized Code:Light PVC HO3VV-F
Ordinary PVC HO5VV-F
Sheath:PVC type TM2 as per BS EN 50363
temperature rating 70 ºC.
(PVC rated 90 ºC or 105 ºC available upon request).
Applications:These cables are used in mobile electrical equipment and units, supply pumps and motors, etc., in which cables with high flexibility are required.
     Type of Conductor
Order No.

Item Code No.
Nominal AreaInsulation ThicknessNominal Sheath ThicknessApprox. Overall Diameter *Approx Weight **Standard Length
Standard Packing 
mm2mmmmmmKg/Kmmtr




Light
F001U1F2-20400F-20002W-42 x 0.500.50.65.038.091.4Coil
F002U1F2-20500F-20002W-42 x 0.750.50.65.545.091.4Coil
F003U1F2-30400F-20002W-43 x 0.500.50.65.345.091.4Coil
F004U1F2-30500F-20002W-43 x 0.750.50.65.755.091.4Coil
F005U1F2-40400F-20002W-44 x 0.500.50.65.855.091.4Coil
F006U1F2-40500F-20002W-44 x 0.750.50.66.365.091.4Coil

















Ordinary
F007U1T2-20600F-20002W-42 x 1.00.60.86.664.791.4Coil
F008U1T2-20800F-20002W-42 x 1.50.70.87.587.091.4Coil
F009U1T2-21000F-20002W-42 x 2.50.81.09.1133.091.4Coil
F010•U1T2-21200F-20002W-42 x 4.00.81.210.6188.091.4Coil
F011•U1T2-21300F-20002W-42 x 6.00.81.211.8246.091.4Coil
F012U1T2-30600F-20002W-43 x 1.00.60.86.977.091.4Coil
F013U1T2-30800F-20002W-43 x 1.50.70.98.2111.091.4Coil
F014U1T2-31000F-20002W-43 x 2.50.81.09.7161.091.4Coil
F015•U1T2-31200F-20002W-43 x 4.00.81.211.3232.091.4Coil
F016•U1T2-31300F-20002W-43 x 6.00.81.412.9322.091.4Coil
F017U1T2-40600F-20002W-44 x 1.00.60.97.895.891.4Coil
F018U1T2-40800F-20002W-44 x 1.50.71.09.2141.091.4Coil
F019U1T2-41000F-20002W-44 x 2.50.81.110.8206.091.4Coil
F020•U1T2-41200F-20002W-44 x 4.00.81.412.7300.091.4Coil
F021•U1T2-41300F-20002W-44 x 6.00.81.414.2405.091.4Coil
F022U1T2-50600F-20002W-45 x 1.00.60.98.4115.091.4Coil
F023U1T2-50700F-20002W-45 x 1.50.71.110.1170.091.4Coil
F024U1T2-50800F-20002W-45 x 2.50.81.212.0245.091.4Coil
F025•U1T2-50900F-20002W-45 x 4.00.81.413.8355.091.4Coil
F026•U1T2-51000F-20002W-45 x 6.00.81.415.4475.091.4Coil
  • The Approx. overall diameter is subject to a tolerance of (-2/+8)%.
  • The Approx. weight is subject to a tolerance of ± 5%.
  • Produced as per BS 6004.

Features:

  • Small diameter saves space.
  • Excellent electric characteristics and mechanical strength.

Color Code:

  • Two-cores: Blue, Brown.
  • Three-cores: Green/yellow, Blue, Brown.
  • Four-cores: Green/yellow, Blue, Brown, Black.
  • Five-cores: Green/yellow, Blue, Brown, Black, Gray.

600 Volts – THHN / THWN AWG Wires

Standard:UL 83Conductor:Annealed solid or stranded copper wires as per UL 83.
Rated Voltage:600 VInsulation:PVC Insulation rating 105 ºC.
Jacket:Nylon jacket provided over PVC insulation for protection from abrasions and scratches at the time of pulling through conduits. It also serves as a protective shield against oil, gasoline and chemicals.
Harmonized Code:Flexible conductor HO7V-KApplications:THHN/THWN building wires are used for general purpose applications such as wiring works at residential, industrial and commercial buildings.


Order No.


Item Code No.


AWG
Equiv.AreaInsulation ThicknessNylon Jacket ThicknessApprox. Overall Diameter *Approx Weight ** Standard Length

Standard Packing
mm2mmmmmmKg/Kmmtr
A001U1A6-16G00R-20000x-F18 •0.820.380.112.412.0152Spool
A002U1A6-15G00R-20000x-F16 •1.310.380.112.717.0152Spool
A003U1A6-14G00R-20000x-F142.080.380.112.925.0152Spool
A004U1A6-13G00R-20000x-F123.310.380.113.438.0152Spool
A005U1A6-12G00R-20000x-F105.260.510.114.360.0152Spool
A006U1A6-11G00R-20000x-F88.370.760.135.697.0152Spool

THHN: Thermoplastic insulated, High Heat-resistant, Nylon jacketed cable, 105 ºC dry locations.

THWN: Thermoplastic insulated, High Water-resistant, Nylon jacketed cable, 75 ºC wet locations.

  • Listed as TFFN wires.
  • The Approx. overall diameter is subject to a tolerance of ± 2 %.
  • The Approx. weight is subject to a tolerance of ± 5%.

Features:

  • Extra-slide properties: The special construction of the insulation assures optimum sliding even in the least favorable circumstances.
  • Excellent flexibility: The use of flexible copper conductors and special PVC compounds makes this cable highly flexible.